Failure Code [Ca442] Battery Voltage High Error - Komatsu PC130-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC130-8:
Table of Contents

Advertisement

SEN04120-03

Failure code [CA442] Battery voltage high error

User code
Failure code
E10
Contents of
• High voltage was detected in controller power supply voltage circuit.
trouble
Action of
• None in particular.
controller
Problem that
appears on
• Engine continues operation normally, but it may stop during operation or may not be able to start.
machine
Related
• Method of reproducing failure code: Turn starting switch ON.
information
Possible causes
and standard
value in normal
state
12
Trouble
CA442
Cause
Carry out troubleshooting for failure code [CA111].
Battery voltage high error
(Engine controller system)
Standard value in normal state/Remarks on troubleshooting
40 Troubleshooting