Operation Of Quick Tuning; Errors In Quick Tuning - Mitsubishi Electric MELSERVO J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO J5 Series:
Table of Contents

Advertisement

Operation of quick tuning

When quick tuning is started, the servo amplifier applies vibration torque instantly, and adjusts each gain and the machine
resonance suppression filter by using the response from that excitation. Vibration torque is applied by 60 % at the maximum
of the rated torque. However, vibration torque is limited by the torque limit value when the torque limit value is less than 60 %
of the rated torque. The adjusting time is approximately 300 [ms]. When the magnetic pole detection is executed, quick tuning
will be started after the magnetic pole detection.
Once gain adjustment by quick tuning is complete, the gain can be changed as in the manual mode. Also, the load to motor
inertia ratio will be always estimated as in the auto tuning mode 1 after the gain adjustment.
Start of quick tuning
Torque
60 % of rated
torque
-60 % of rated
torque
Speed
Approx. 300 [ms]
The following servo parameters are adjusted automatically in quick tuning.
No.
Symbol
Name
PB01
FILT
Adaptive tuning mode (adaptive filter II)
PB06
GD2
Load to motor inertia ratio
PB07
PG1
Model control gain
PB08
PG2
Position control gain
PB09
VG2
Speed control gain
PB10
VIC
Speed integral compensation
PB11
VDC
Speed differential compensation
PB13
NH1
Machine resonance suppression filter 1
PB14
NHQ1
Notch shape selection 1
PB15
NH2
Machine resonance suppression filter 2
PB16
NHQ2
Notch shape selection 2
PB18
LPF
Low-pass filter setting
PB23.1
Low-pass filter selection
PB50
NH5
Machine resonance suppression filter 5
PB51
NHQ5
Notch shape selection 5
PE41
EOP3
Function selection E-3

Errors in quick tuning

When the following conditions are met, quick tuning may fail:
• When torque is reached to torque limit value during quick tuning
• When the travel distance in quick tuning exceeds the set value in [Pr. PA34 Quick tuning - Permissible travel distance]
When quick tuning fails, the servo parameters before quick tuning will be restored.
Gain adjustment complete
Setting value after gain adjustment
Automatic setting
The setting value is set depending on the response waveform during servo motor
driving after gain adjustment.
Automatic setting
Initial value
Automatic setting
Initial value
1
Automatic setting
Initial value
Time
Time
3 ADJUSTMENT METHOD
3.1 Quick tuning
3
15

Advertisement

Table of Contents
loading

Table of Contents