Mitsubishi Electric C80 Series Connection And Set Up Manual page 75

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Connection and Setup Manual
4 General Specifications
(5) CN1
Connector for servo/spindle drive unit
1
2
(6) DISPLAY I/F
Connector for display (GOT)
1
8
(7) EMG
Connector for the emergency stop signal input
1
2
70553-0001
(MOLEX)
Input type: Current sinking/sourcing
Insulation method: Photocoupler insulation
Input voltage: 24VDC (+10%, -15%, ripple ratio within 5%)
OFF voltage/current : 17.5VDC or more / 3.0mA or less
ON voltage/current : 1.8VDC or less / 0.18mA or less
Input resistance: Approximate 10kΩ
Response time (OFF -> ON or ON -> OFF): 1ms
Applicable size of wire : 0.3mm
IB-1501452-C
1
IN
RD
2
OUT
TD
1
OUT
TD+
2
OUT
TD-
3
IN
RD+
4
CMTR
5
CMTR
6
IN
RD-
7
CMIT
8
CMIT
1
IN
EMG.COM
2
IN
EMG
2
2
10kΩ
EMG
1
EMG.COM
44