Problem solving guide
Problem
F234
Too much ground coffee
Check water intake
Push the water container in
until it engages
80
Cause and remedy
Cup protection cut-out has been activated three
times since switching on the coffee machine. The
cups or glasses being used are not recognised by the
automatic spout adjustment.
 Use cups or glasses which can be recognised by
the automatic spout adjustment.
There is a fault with the automatic spout adjustment.
 Switch the machine off with the On/Off sensor .
Wait for approx. 2 minutes before switching it back
on again.
There is too much ready ground coffee in the ground
coffee chute.
If more than one level spoon of ground coffee is
added to the coffee chute, the brew unit cannot
process the coffee. The ground coffee will be directed
into the waste container and the fault message will
appear in the display.
 Switch the coffee machine off with the On/Off
sensor .
 Remove and clean the brew unit (see "Cleaning
and care – Brew unit").
 Remove the ground coffee inside the coffee
machine, e.g. with a vacuum cleaner.
 Use the coffee spoon supplied to add ground
coffee to the ground coffee chute. Add only one
portion of ground coffee to the chute.
There is a problem with the mains water inlet.
 Check whether the inlet hose is kinked or the
stopcock is not turned on completely.
 Remove and empty the water container.
 Push the water container back in the machine,
making sure it is positioned correctly.
The water container is not in the correct position.
 Remove the water container and replace it.
This fault message also appears if the water container
was not correctly filled and replaced for descaling.
 Fill the water container to the descaling symbol 
and restart the descaling process.