Problem
The compressor comes
on less and less often
and for shorter periods
of time. The temperat-
ure in the appliance
rises.
An LED indicator light is
flashing at the back of
the appliance at the
bottom near the com-
pressor (depending on
model).
Cause and remedy
This is not a fault. The set temperature is too high.
Adjust the temperature.
Check the temperature again after 24 hours.
The food begins to defrost.
The room temperature is lower than the ambient tem-
perature for which the appliance is designed.
Operating in a room which is too cold will cause the
compressor to switch off for too long, causing the
freezer to become too warm.
See "Installation - Location".
Increase the temperature of the room.
This is not a fault. The electronic unit for the com-
pressor is equipped with an operation and fault dia-
gnosis LED indicator light which flashes every 15
seconds (depending on model).
Problem solving guide
37