Page 4
In no event shall ABB be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, nor shall ABB be liable for incidental or consequential damages arising from use of any software or hard- ware described in this document.
Page 6
Agency Approvals and Standards Compliance ................25 Notice: FCC Part 15.105......................25 Safety Control Drawing ........................26 AC Power Supply ..........................27 Type Tests and Environmental Conditions....................28 Referring Documents .........................31 Cable Factory Reset on NE840 ......................31 Proceed with Factory Reset ......................31 Skip the Factory Reset ......................32 3BSE080639...
Safety Warning Do not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations. To reduce the risk of fire, use on No. 26 AWG or larger telecommunication line cord.
SFP transceivers. NE804 is powered by the ABB Network Operating System (ABB NEOS). NE840 is designed for 19” cabinet according to ETSI standard making it suitable for use in control room networks as well as for cabinets installed along railway track side or maritime installations.
Page 10
Section 1 Industrial Routing Switch RaMa 19P - 4PG - 7RG Figure 1. Housing NE840 Specification Dimension W x H x D 480 x 43 x 258 mm 18,9 x 1,66 x 10,16” Weight 3.8 kg Degree of protection IP40 according to EN 60529...
Section 2 Interface specifications Console Electrical specification USB 2.0 device interface Data rate High speed 480mbit/s Circuit type SE LV Maximum supply current 100 mA Isolation to All other except USB Galvanic connection to Connection USB Micro-B connector in device mode Figure 5.
Section 2 Interface specifications SFP Ports Optical/Electrical IEEE std 802.3. 2005 Edition specification Data rate 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s Duplex Full or half, manual or auto Transmission range Depending on transceiver Connection SFP slot holding fibre transceiver or copper transceiver * 100 Mbit/s or 1000 Mbit/s transceiver supported.
Page 18
Section 2 Interface specifications IO / Relay Output Connect resistance 30 W Isolation to All other Connection Detachable screw terminal Connector size 0.2 – 2.5 mm (AWG 24 – 12) Maximum voltage/ 60 VDC / 80 mA current 3BSE080639...
Page 19
Section 2 Interface specifications IO / Digital Input Voltage levels > 8V Vil < 5V = 2.9mA @60V Isolation to All other Connection Detachable screw terminal Connector size 0.2 – 2.5 mm (AWG 24 – 12) Maximum voltage/ 60 VDC current 3BSE080639...
Section 2 Interface specifications LED Indicators Power/CPU Status Description Unit has no power GREEN All OK, no alarm condition Alarm condition, or until unit has started up. (Alarm conditions are configurable, refer to NEOS User Manual. Location indicator Here I am. Activated when connected to BLINK IPConfig Tool, or upon request from Web or CLI.
Section 2 Interface specifications Modular Transceivers For supported modular transceivers, refer to Modular Transceivers User Guide (3BSE080641). The unit supports ABB transceivers only. Mounting This unit can either be rack-mounted or wall-mounted. Rack Mounting For mounting into rack, use M6x25 or 1/4”x1” screws as shown in Figure Figure 10.
Section 2 Interface specifications Wall Mounting If mounting onto a wall as shown in Figure 11, use maximum Ø6,4 mm or 1/4” screws. Figure 11. Wall Mounting Earth Connection For correct function, the ground connection on the unit needs to be properly connected to a solid ground as shown in Figure RaMa 19P - 4PG - 7RG...
Section 2 Interface specifications Getting Started This product runs ABB Network Equipment Operating System (NEOS) which provides several management tools that can be used for configuration of the unit. NeCo - is a Network configuration management tool (NCM) made for commissioning and maintenance of components in a network.
Section 2 Interface specifications Once you have logged in, you can use the extensive integrated help function describing all configuration options. Two common task when configuring a new switch is to assign appropriate IP settings, and to change the password of the admin account.
Section 2 Interface specifications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Safety Control Drawing RaMa 19P - 4PG - 7RG Figure 13.
Section 2 Interface specifications AC Power Supply Degree of protection IP 40 Ambient temperature –40°C to +70°C * Direction relative this unit! 3BSE080639...
Section 2 Interface specifications Type Tests and Environmental Conditions Environmental Test Description Test levels phenomena EN 61000-4-2 Enclosure contact ±6 kV Enclosure air ±8 kV RF field AM IEC 61000-4-3 Enclosure 20 V/m 80% AM (1 kHz), 80 – 2700 MHz modulated 10V/m 80% AM (1 kHz), 2700-6000 MHz Fast transients EN 61000-4-4...
Page 29
Section 2 Interface specifications Surge EN 61000-4-5 Power port ± 2 kV line to earth, ± 1 kV line to line Signal ports ± 2 kV line to earth, ± 1 kV line to line RF conducted EN 61000-4-6 Power port 10 V 80% AM (1 kHz), 0.15 –...
Page 30
Section 2 Interface specifications Humidity Operating 5 to 95% relative humidity Storage and transport 5 to 95% relative humidity Altitude Operating 2 000 m / 70 kPa Service life Operating 10 years 7.5 mm, 5 – 8 Hz Vibration IEC 60068-2-6 Operating 2 g, 8 –...
System 800xA 6.0 Network Guide Configuration Guide Cable Factory Reset on NE840 It is possible to set the unit to factory default settings by using two straight standard Ethernet RJ-45 cables. 1. Power off the switch and disconnect all Ethernet cables (copper and fibre).
Section 2 Interface specifications Skip the Factory Reset To skip the factory reset process, just wait for approximately 30 seconds (after the ON LED starts flashing RED) without unplugging the Ethernet cables. The switch will conduct a normal boot with the existing settings. Do not power off the unit while the factory reset process is in progress.