Panasonic GT Series Manual page 111

Connection with other companies’ plcs
Hide thumbs Also See for GT Series:
Table of Contents

Advertisement

Communication Parameters Settings
The example of communication settings of GT and PLC is shown below.
Setting Values for GT (Set in the configuration setting of GTWIN.)
Item
Baud Rate
Data Length
Stop Bits
Parity Bit
Setting Values for PLC
Setting for -CPU104A/EH-CPU208A/EH-CPU316A/EH-CPU516/EH-CPU548
When using Port 1
The settings for the dip switches and special internal output are required.
Set the dip switches of CPU module as follows.
Item
Port type
Baud rate
Set the special internal output as follows.
Item
Interface *1
Procedure of communication control
*1 It varies according to the communication method.
*2 The procedure 1 of transmission control with unit number cannot be used.
*3 For the details of the method of communication setting, refer to the "EH-150 Application Manual".
When using Port 2
The setting of the dip switches is required.
The PHL switch must be "ON". It cannot be used if the switch is "OFF".
Set the dip switches of CPU module as follows.
Item
Port type
Baud rate
Procedure of communication control
*1 As it is fixed, the setting is not required.
*2 For the details of the method of communication setting, refer to the "EH-150 Application Manual".
Setting
19200bps
7
1
Even
Setting
Setting for special port
19200 bps
For RS232C connection: RS232C
For RS422 connection: RS422 internal terminating resistance
function is ON.
For RS485 connection: RS422 internal terminating resistance
function is ON.
Procedure 1 of transmission control (No unit No.) *2
Setting for special port *1
19200bps
Procedure 1 of transmission control (No unit No.)
Setting
Setting
9-3