Application; Feeder Application - ABB REX640 Product Manual

Hide thumbs Also See for REX640:
Table of Contents

Advertisement

REX640
Product version: 1

5. Application

3I
U
Io
GUID-71448271-EE0E-4E5B-BCB6-671CEB238139 V2 EN
Figure 7.

Feeder application

Figure 7
presents REX640 in a feeder application. The base
functionality is enhanced with application packages providing
both line distance and line differential protections. To provide
10
REX640
PROTECTION AND CONTROL RELAY
Example of a combination of application packages for feeder protection
PROTECTION
Master Trip
94/86
3U<
U1<
3U<R
3I<
27
27PS
27R
37
I2/I1>
3Ith>F
3I>/Io>BF
46PD
49F
50BF
Io>>
Io>
3I>
3I>>>
51G/
51G/
51P-1
50P
51N-1
51N-2
3I(U)
3U>
Uo>
U2>
51V
59
59G/59N
59NS
3I>→
Io>→
Io>>→
3I>>→
67P/
67G/N-1
67G/N-2
67P/
51P-1
51P-2
51G/N-1
51G/N-2
12×
3I2f>
f>/f<,df/dt
UFLS/R
68HB
81
81LSH
24×
CVPSOF
dIoLo>
ARC
MAP
SOFT
87NLI
AFD
MAP
APPLICATION PACKAGE FOR FEEDER EF PROTECTION EXTENSION
Yo>→
Po>→
Io>HA
I2→,Io→
21NY
32N
51NH
67N-TC
Io>→IEF
Io>→Y
HIF
67NTEF/NIEF
67NYH
HIZ
APPLICATION PACKAGE FOR FEEDER FAULT LOCATOR
FLOC
FLOC
APPLICATION PACKAGE FOR LINE DISTANCE PROTECTION
LAL
Φ <
85 21CREV,WEI
21LAL
78PS
CLCRWN
CL
85 67G/N CREV,WEI
85 21SCHLGC
CLN
BST
85 67G/N SCHLGC
BST
APPLICATION PACKAGE FOR LINE DIFFERENTIAL PROTECTION
B)
3Id/I>
BST
87L
BST
LOCAL HMI (OPTIONAL)
I2>M
46M
- 7-inch color touch screen
Io>>>
- Ready-made pages and
50G/50N
customizable pages
- Increased situational awareness
towards process
3I>>
- Supports Relay testing and
51P-2
commissioning
- Graphical editing of pages with
PCM600 tool
U1>
59PS
CONDITION MONITORING
AND SUPERVISION
I2>→
67Q
CBCM
dIoHi>
MCS 3I
52CM
87NHI
OPTS
OPTM
A)
PCS
PCS
CONTROL AND INDICATION
Object
CB
DC, 3 state
APP1
DC
ES
Control and status indication function for
1)
primary object
Status indication function for primary
2)
object
APP2
CLCRW
SYNC
25AU-
25
TOSYNC
REMARKS
B)
Total nr. of instances
One instance available, common for
A)
APP3
Line Distance (APP3) and Line
Differential (APP4) application
packages
Two instances available, common
B)
for Line Distance (APP3) and Line
Differential (APP4) application
packages
APP4
additional protection against earth faults along the feeder, an
additional application package has been selected.
Conventional measuring transformers are used in the example
ALSO AVAILABLE
- Disturbance and fault recorders
- Sequence event recorder
- Relay self-supervision
- User management and logging
- Logical and mathematical functions
- WebHMI
COMMUNICATION
Protocols:
IEC 61850-8-1/-9-2LE
Modbus
IEC 60870-5-103
DNP3
Interfaces:
CCM
Ethernet: TX (RJ45), FX (LC)
Serial:
TCS
FUSEF
Redundant protocols:
TCM
VCM, 60
HSR
PRP
Time synchronization:
SNTP
PTPv2
IRIG-B
APP3 / APP4
MEASUREMENT
- I, U, Io, Uo, P, Q, E, pf, f
Ctrl
Ind
1)
2)
- Sequence current/voltage measurement
3
-
- Limit value supervision
- RTD/mA measurement and mA output
6
6
8
8
Analog interface types
3
3
Current transformer
Voltage transformer
1)
One of available current transformer
inputs is sensitive (0.2/1 A)
O→I
LOADPROF
79
LOADPROF
PQM3IH
PQM ITHD, IDC
PQM3VH
PQM VTHD, VDC
PQMU
PQMV SWE,SAG,
INT
PQUUB
PQMV UB
1MRS759144 A
AND
OR
®
Serial glass fiber (ST),
RS-485
1 0 1 0 0 0 1 1 0 0 1 1 0 0
1 0 1 1 0 0 1 0 1 1 1 0 0 1 0
1 1 0 0 1 1 1 0 1 1 0 1 0
1 0 1 1 0 1 1 0 1 1 0 1 0 0
1 0 1 0 0 0 1 1 0 0 1 1 0 0 1 0 1 0 0
1 0 1 1 0 0 1 0 1 1 1 0 0 1 0
1 1 0 0 1 1 1 0 1 1 0 1 0
1 0 1 1 0 1 1 0 1 1 0 1 0 0
AIM1
5
1)
5
ABB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents