Siemens Electrical Lean Switch Installation Instructions Manual page 30

Industrial ethernet electrical lean switch
Table of Contents

Advertisement

Ports and Displays
Warning
!
Industrial Ethernet ELS TP40M switches are designed for operation with safety
extra-low voltage. This means that only safety extra-low voltages (SELV)
complying with IEC950/EN60950/ VDE0805 can be connected to the power supply
terminals.
The power supply unit to supply the ELS TP40M must comply with NEC Class 2
(voltage range 18 - 32 V, current requirement 150 mA).
Never connect the ELS to a.c. power supplies or d.c. power supplies greater than
32 V d.c.
Power Supply
The power supply is connected over a high resistance with the enclosure to allow
an ungrounded setup. The ELS TP40M device can also be grounded using the PE
screw terminal on the terminal block.
30
Industrial Ethernet
A5E00152007-03