Siemens DTU3005-B Operator's Manual page 28

Intelligent data transfer device for connection to plcs and modbus networks
Table of Contents

Advertisement

4
Creating Project Files—PLC to Devices
The relevant status codes (Text #) are listed below.
Table 4.1 7SJ600 Relay Information
For Requesting Status of the 7SJ600 Relay's Three Binary Inputs
Text Number/Status Code
(default value returned if
not converted)
1342
1343
1344
1345
1346
1347
1348
For Requesting Status of the 7SJ600 Relay's Two Trip Contacts and Two Signal Contacts
Text Number/Status Code
(default value returned if
not converted)
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
For Requesting Status of the 7SJ600 Relay's Four Programmable LEDs
Text Number/Status Code
(default value returned if
not converted)
1365
1366
1367
1368
1369
1370
1371
24
Description of Returned Binary
Input Status Codes: I1
indicates Input 1; I2,3 indicates
Inputs 2 and 3
I1,2 Inactive : I3 Active
I1,3 Inactive : I2 Active
I1 Inactive : I2,3 Active
I2,3 Inactive : I1 Active
I2 Inactive : I1,3 Active
I3 Inactive : I1,2 Active
I1,2,3 Active
Description of Returned Trip
and Signal Relay Status
Codes: S1,2 indicates Signal
Relays 1 and 2; T1,2 indicates
Trip Relays 1 and 2
S1,2 T1,2 Open
S1,2 T1 Open : T2 Closed
S1,2 T2 open : T1 Closed
S1,2 Open : T1,2 Closed
S1 T1,2 Open : S2 Closed
S1 T1 Open : S2 T2 Closed
S1 T2 Open : S2 T1 Closed
S1 Open : S2 T1,2 Closed
S2 T1,2 Open : S1 Closed
S2 T1 Open : S1 T2 Closed
S2 T2 Open : S1 T1 Closed
S2 Open : S1 T1,2 Closed
T1,2 Open : S1,2 Closed
T1 Open : S1,2 T2 Closed
T2 Open : S1,2 T1 Closed
S1,2 T1,2 Closed
Description of Returned LED
Status Codes: L1,2 indicates
LEDs 1 and 2
L1,2,3,4 Off
L4 On : L1,2,3 Off
L3 On : L1,2,4 Off
L3,4 On : L1,2 Off
L2 On : L1,3,4 Off
L2,4 On : L1,3 Off
L2,3 On : L1,4 Off
Suggested Value (Using This Conversion Table)
Inputs
I3
Value
0
0
0
4
0
1
2
0
0
6
0
1
1
0
0
5
0
1
3
0
0
7
0
1
Suggested Value (Using This Conversion Table)
Outputs
S2
Value
Bits 15 . . . 4
3
0
0
0
2
0
0
1
0
0
3
0
0
8
0
1
10
0
1
9
0
1
11
0
1
4
0
0
6
0
0
5
0
0
7
0
0
12
0
1
14
0
1
13
0
1
15
0
1
Suggested Value (Using This Conversion Table)
Outputs
L4
Value
Bits 15 . . . 4
3
0
0
0
8
0
1
4
0
0
12
0
1
2
0
0
10
0
1
6
0
0
Siemens Energy & Automation, Inc.
I2
I1
0
0
0
0
1
0
1
0
0
1
0
1
1
1
1
1
S1
T2
T1
2
1
0
0
0
0
0
1
0
0
0
1
0
1
1
0
0
0
0
1
0
0
0
1
0
1
1
1
0
0
1
1
0
1
0
1
1
1
1
1
0
0
1
1
0
1
0
1
1
1
1
L3
L2
L1
2
1
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
0
0
1
0
1
1
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents