Java User's Guide
8.6 Procedures
63
the old and the new application at the same time, the old application is deleted before the down-
load of the new one, therefore it is lost when an error occurs.If install/update was successful,
autostart is set to the new application.
8.6.2

Delete

Figure 21: OTAP: Delete Information Flow (messages in brackets are optional)

When an SM with keyword START: delete is received and there is a valid parameter set for this
operation, the module reboots either when the operation completed, an error occurred or the
safety timer expired. If there is any error the application is kept untouched. Autostart is not
changed.