Panasonic AMK3000P22 Installation Manual page 41

Mk300 series. 1-phase 200v(0.2kw-2.2kw), 3-phase 400v(0.75kw-15kw)
Table of Contents

Advertisement

Function
Changes
No.
name
during RUN
Operation
P005
Status
Monitor
Vector
P006
Control
Selection
Carrier
P007
frequency
S-shaped
Acceleration
P008
/Deceleration
Mode
P009 V/FMode
P010 V/FCurve
Torque
P011
Boost*7
Maximum
P012
Output
Frequency
Base
P013
Frequency
Change
Point
P014
Frequency
1
Change
P015
Point
Voltage 1
Change
Point
P016
Frequency
2
Change
P017
Point
Voltage 2
Maximum
P018
Output
Voltage
JOG
P019
Frequency
0: Output frequency
1: Linear speed
2: Output current
3: Communication station
No.
4: Setting frequency
0: V/F control
1: Sensorless vector control
During V/F control: 0.8 to 15.0 (9 steps)
During sensorless vector control: 2.5 to 15.0 (6 steps)
0: Linear acceleration/deceleration
1: S-shaped acceleration/deceleration (Quadratic
curve)
2: S-shaped acceleration/deceleration (Cubic curve)
50 : 50Hz mode
60 : 60Hz mode
FF : Free mode
3C : 3-point type
3C1 : 3-point fixing 1
0: Constant torque mode
1: Reduced torque mode
0 to 40: Manual torque boost
Auto: Automatic torque boost
50.0 to 400.0
45.0 to 400.0
0.2 to 400.0
0.0 to 100.0
0.2 to 400.0
0.0 to 100.0
0(Power supply voltage), 1 to 500
0.2 to 400.0
Setting range
5: Communication station
No./Output frequency
6: Communication station
No./Linear speed
7: Communication station
No./Output current
8: Winding length
3C2 : 3-point fixing 2
3C3 : 3-point fixing 3
3C4 : 3-point fixing 4
3C5 : 3-point fixing 5
3C6 : 3-point fixing 6
Initial
Unit
value
0
0
[kHz]
2.5
0
50
0
1[%]
*4
0.1[Hz]
50.0
0.1[Hz]
50.0
0.1[Hz]
0.2
0.1[%]
0.0
0.1[Hz]
0.2
0.1[%]
0.0
1[V]
0
0.1[Hz]
10.0
40

Hide quick links: