Program
Program Name/Description
Number
Outbound IP Connection Setup – IP Address
90-69-02
Define the IP Address that the System will
make the TCP establishment request to. I.E.
the IP address of the PC with the waiting PC
Programming.
Outbound IP Connection Setup – Caller ID
90-69-03
Define Caller ID number that the system to
compare with received Caller ID.
Operation
Outbound IP Connection
1.
Open PC Pro on PC that has same IP address as assigned in Program 90-69-02.
2.
Go to Communications/Connect.
3.
Select Outbound IP.
4.
Input Connection port (same as Program 90-69-01).
5.
Select Connect.
When PCPro does not receive a TCP established request within three minutes (fixed time), it ends the
state of "Attempting to Connect".
6.
Dial Outbound IP Connection Service Code (Program 11-15-16).
-OR-
7.
Call the DID that points to the Outbound IP Connection Service Code (Program 11-15-16) with
the matching CID (Program 90-69-03).
8.
After connection hang up.
Input Data
0.0.0.0 ~ 255.255.255.255
Maximum of 16 digits
*
#
(0 ~ 9,
,
9)
983
Default
0.0.0.0
No Setting

Advertisement