6.11 Specifications

Parameter
Intended Uses
Installation Type
Material
Pipe Sizes
Operating Frequency
Electrical Rating
Ambient Temperature Range -40 to +167°F (-40 to +75°C)
Process Temperature Range -40 to +302°F (-40 to +150°C)
North American Certification
- Explosion proof
European Certification -
Flameproof
North American Certification
- Weatherproof
European Certification
- Weatherproof
The transducer is protected by a suitable fuse located in the flowmeter electronics.
IMPORTANT:
The fuse has a breaking capacity in accordance with the short circuit current of the supply.
C-RS Ultrasonic Flow Transducer Installation Guide
Table 4: C-RS Transducer Specifications
401
Large pipes
Ductile iron pipes
Lined pipes
Two-phase liquid
High performance
Clamp-on for liquid applications
316 Stainless Steel or plastic
2" to 300" (5 cm to 7.5 m)
diameter
0.5 MHz
200 V peak-to-peak, 5 mA
Class I, Division 1, Group B, C & D
II 2 GD, EEx md IIC T6 80°C
o
Tam -40 to 75
C (-40 to 167
KEMA 02ATEX2337 X
IP66, TYPE 4X
200Vpp, 5mA
IP 66
Transducer #
402
Mid-size pipes
High performance
2" to 300" (5 cm to 7.5 m)
diameter
1.0 MHz
o
F)
403
Small pipes;
High performance
2" to 6" (5 to 15 cm)
diameter
2.0 MHz
43