5.3 The Double-Traverse Method -UCF (cont.)
6. Wrap the chain around the pipe and fasten the chain on the "J" screw hook on the opposite side of the block. Do
this for both blocks.
Top View
7. Using the screw hook on the blocks, tighten the chains until the fixture is secured snugly to the side of the pipe.
Note: Make sure the chains are perpendicular to the clamping fixture and are not twisted. If the chains are slanted,
the fixture may move and this could change the final transducer spacing.
Figure 5 shows a completed double-traverse installation without transducers.
Side View
Top View
Figure 5: Double-Traverse Clamping Fixture w/o Transducers
10
C-RS Ultrasonic Flow Transducer Installation Guide