05.05
PNU
Description
P626
Source for actual speed controller value
*
Selection of connector to be injected as the input signal for actual speed
FDS
value filtering
0 = connector K0000
(G152)
1 = connector K0001
etc.
P627
Source for input of D element
*
Selection of connector to be injected as the input signal for the D element
(G152)
0 = connector K0000
1 = connector K0001
etc.
P628
Source for input of band-stop filter 1
*
Selection of connector to be injected as the input signal for band-stop filter 1
(G152)
0 = connector K0000
1 = connector K0001
etc.
P629
Source for band-stop filter 2
*
Selection of connector to be injected as the input signal for band-stop filter 2
(G152)
0 = connector K0000
1 = connector K0001
etc.
Speed controller droop
P630
Source for influencing quantity for speed droop
*
Selection of connector to be injected as the influencing quantity
(G151)
0 = connector K0000
1 = connector K0001
etc.
Setting the speed controller I component
Function: When the binector selected in P695 switches state from log. "0" to log. "1", the I component of the speed controller is set to the
value of the connector selected in P631.
With this function it is possible, for example, to use the same signal (binector) to control controller enabling commands and
setting of the I component.
P631
Source for setting value for speed controller integrator
*
Selection of connector to be injected as the setting value for the I
component
(G152)
0 = connector K0000
1 = connector K0001
etc.
Setting values for configuring the setpoint processing function and ramp-function generator
Limitation at ramp-function generator output (setpoint limitation)
(see also Section 8, Sheet G136)
The effective limitations are:
Upper limit:
Minimum value of P300 and the four connectors selected with P632
Lower limit:
Maximum value of P301 and the four connectors selected with P633
Note:
The limiting values for both the positive and negative setpoint limits can have a positive or negative sign. The negative setpoint
limit, for example, can therefore be parameterized to a positive value and the positive setpoint limit to a negative value.
P632
Source for variable positive limitation at ramp-function generator
*
output
Selection of connectors to be injected at the variable positive limitation at
(G137)
the ramp-function generator output (setpoint limitation).
0 = connector K0000
1 = connector K0001
etc.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All connector
Ind: 4
numbers
FS=167
1
Type: L2
All connector
Ind: None
numbers
FS=178
1
Type: L2
All connector
Ind: None
numbers
FS=179
1
Type: L2
All connector
Ind: None
numbers
FS=177
1
Type: L2
All connector
Ind: None
numbers
FS=162
1
Type: L2
All connector
Ind: None
numbers
FS=0
1
Type: L2
All connector
Ind: 4
numbers
FS=1
1
Type: L2
Parameter list
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
11-67