Table 4- 3
Frame size
kW
FSA
0.37:
0.55:
0.75:
1.1:
1.5:
2.2:
3:
FSB
4:
5.5:
7.5:
FSC
11:
15:
18.5:
FSD
22.0
30.0
FSE
37.0
45.0
FSF
55.0
75.0
90.0
PM230 Power Module IP55
Hardware Installation Manual, 11/2014, A5E35319202B AA
Cable cross-section
Cable cross-section
mm
AWG
2
1.0 ... 2.5
18 ... 14
1.0 ... 2.5
18 ... 14
1.0 ... 2.5
18 ... 14
1.0 ... 2.5
18 ... 14
1.0 ... 2.5
18 ... 14
1.5 ... 2.5
16 ... 14
1.5 ... 2.5
16 ... 14
2.5 ... 6.0
14 ... 10
4.0 ... 6.0
12 ... 10
4.0 ... 6.0
12 ... 10
6.0 ... 16
10 ... 5
10 ... 16
7 ... 5
10 ... 16
7 ... 5
10 ... 35
5 ... 2
10 ... 35
3 ... 2
25 ... 50
3 ... 2
35 ... 50
2 ... 4/0
70 ... 120
2/0 ... 4/0
95 ... 120
3/0 ... 4/0
95 ... 120
3/0 ... 4/0
4.3 Motor cable lengths and cross-sections
Tightening torques
Nm
lbf in
0.5
4.4
0.5
4.4
0.5
4.4
0.5
4.4
0.5
4.4
0.5
4.4
0.5
4.4
0.6
5.3
0.6
5.3
0.6
5.3
1.5
13.3
1.5
13.3
1.5
13.3
6
53
6
53
6
53
6
53
13
115
13
115
13
115