Replacing A Failed Hard Drive - Bosch DVA-08K Installation Manual

Raid subsystem scsi premium series
Hide thumbs Also See for DVA-08K:
Table of Contents

Advertisement

RAID Subsystem DVA-08K | Installation Manual
6.7.2

Replacing a Failed Hard Drive

To replace a hard drive, please follow these steps:
CAUTION!
CAUTION!
The hard drives and drive trays should only be installed into the subsystem once the sub-
system has been mounted into a rack cabinet. If the hard drives are installed first, the sub-
system will be too heavy to place into position and the possible impact during installation may
damage your drives.
Hard drives for the subsystem can be purchased separately. When purchasing the hard drives,
the following factors should be considered:
1.
CAUTION!
Replacing the wrong drive in an array can fatally fail a RAID configuration. You should identify
a failed drive from the Bosch RAIDWatch GUI screen, by checking the drive slot ID in the termi-
nal screen, by checking the LEDs on the drive tray panel, and/or use the identify/flash drive
function in firmware.
2.
Fig. 6.8 Front View of an Individual Drive Tray
Bosch Security Systems
the drive tray slot open for an extended period of time. If the drive tray slot is left unoccu-
pied for an extended period of time, the airflow will be disrupted and subsystem compo-
nents will overheat and may be permanently damaged.
Handle hard drives with extreme care. Hard drives are very delicate. Dropping a drive
onto a hard surface (even from a short distance) and hitting or touching the circuits on
the drives with your tools may all cause damage to drives.
Observe all ESD prevention methods when handling hard drives.
Only use screws supplied with the drive canisters. Longer screws may damage the drive.
Capacity (MB/GB): Use drives with the same capacity. RAID arrays use a "least-common-
denominator" approach. The maximum capacity of each drive used in the array is the
maximum capacity of the smallest drive. Use drives of the same capacity.
Profile: The drive trays and bays of the system are designed for 3.5-inch wide x 1-inch
high hard drives. It is highly recommended that you do not try to use drives of any other
size.
Drive type: The subsystem can use either SATA-II or SATA-I hard drives.
Identify the drive tray that contains the hard drive that needs to be replaced.
Open the front flap: Once the drive tray has been identified, push the release button at
the drive bezel. (See Figure 6.8) The front bezel will automatically be lifted and the drive
tray should be easily dislodged from the chassis.
Subsystem Maintenance | en
F.01U.027.797 | V1 | 2006.05
45

Advertisement

Table of Contents
loading

Table of Contents