UPnP Enable
Default: Yes
Selections: Yes, No
Yes: UPnP is enabled.
No: UPnP is disabled.
Universal Plug and Play (UPnP) allows devices to connect seamlessly and simplifies the
implementation of personal and corporate networks. When enabled in the premises router,
this feature is used to automatically setup port forwarding rules for Remote Programming
traffic to the control panel.
HTTP Port Number
Default: 80
Selections: 1 to 65535
Use this option to configure the port number for the module web server.
ARP Cache Timeout
Default: 600
Selections: 1 to 600 (in 1-sec increments)
When the module communicates with any device on a network, an entry is added to its ARP
table for each of those devices. The ARP Cache Timeout defines the number of seconds (1 to
600) before the ARP table of the module is refreshed.
5.3.6

Panel Address Settings page

The Panel Address Setting page only allows configuration when the address switch on the
module is set to 0. If the address switch is set to a position other than 0, the set address is
displayed.