Special relays (SM)

MELSEC-L series/Q series
The special relays (SM) which can be used for MELSEC-L series/Q series are as follows.
Number
Name
SM606
SD memory card forced
disable instruction
SM1435
iQ Sensor Solution
backup/restoration
execution enabled
SM1436
iQ Sensor Solution
backup request
SM1437
iQ Sensor Solution
backup normal
completion
SM1438
iQ Sensor Solution
backup abnormal
completion
SM1439
iQ Sensor Solution
restoration request
SM1440
iQ Sensor Solution
restoration normal
completion
SM1441
iQ Sensor Solution
restoration abnormal
completion
SM1442
iQ Sensor Solution
backup/restoration
cancellation request
APPX
356
Appendix 6 Special Relay (SM)/Special Register (SD) List
Description
Details
OFF: Cancel instruction
When this relay is turned ON, the instruction that forcibly disables an
ON: Forced disable
SD memory card is issued. If any function accesses the SD memory
instruction
card, the disabling process does not start until the access is completed.
When this relay is turned OFF, the instruction that forcibly disables an
SD memory card is issued.
OFF to ON: Execution
Data backup/restoration is enabled when this relay turns ON. (Enabled
enabled
only when SD1446 is '3H' (completed), '11H' (cancelled (no error)),
'FEH' (cancelled (error)), or 'FFH' (error).)
This relay turns OFF when the data backup/restoration is enabled.
OFF to ON: Backup
Data backup is performed for the target module type set when this relay
requested
turns ON. (Enabled only when SD1446 is 1H (ready))
This relay turns OFF when the right-to-use is acquired or when data
backup/restoration is enabled.
OFF: Backup incomplete
This relay turns ON when data backup is complete normally.
ON: Backup complete
This relay turns OFF when the right-to-use is acquired.
normally
OFF: Backup incomplete
This relay turns ON when data backup is complete abnormally.
ON: Backup completed with
This relay turns OFF when the right-to-use is acquired.
error(s)
The error code is stored in SD1452 or SD1453.
OFF to ON: Restoration
Data restoration is performed for the target module type set when this
requested
relay turns ON. (Enabled only when SD1446 is '1H' (ready))
This relay turns OFF when the right-to-use is acquired.
OFF: Restoration
This relay turns ON when data restoration is complete normally.
incomplete
This relay turns OFF when the right-to-use is acquired.
ON: Restoration complete
normally
OFF: Restoration
This relay turns ON when data restoration is completed abnormally.
incomplete
This relay turns OFF when the right-to-use is acquired.
ON: Restoration completed
The error code is stored in SD1452 or SD1453.
with error(s)
OFF to ON: Backup/
Data backup/restoration is cancelled when this relay turns ON.
restoration
(Enabled only when SD1446 is 1H (ready) and SD1446 is 2H (being
cancellation requested
executed))
This relay turns OFF when the right-to-use is acquired or when data
backup/restoration is enabled.
Set by
(setting
timing)
U
S (status
change)/U
S (status
change)/U
S (status
change)
S (status
change)
S (status
change)/U
S (status
change)
S (status
change)
S (status
change)/U