Fujitsu ETERNUS DX Configuration Manual

Server connection, fcoe for vmware esx driver settings for non-fujitsu converged network adapter cards
Hide thumbs Also See for ETERNUS DX:

Advertisement

P3AM-4772-11ENZ0
FUJITSU Storage
ETERNUS DX
Configuration Guide -Server Connection-
®
(FCoE) for VMware
ESX
Driver Settings for Non-Fujitsu Converged Network Adapter Cards

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ETERNUS DX

  • Page 1 P3AM-4772-11ENZ0 FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- ® (FCoE) for VMware Driver Settings for Non-Fujitsu Converged Network Adapter Cards...
  • Page 2 This page is intentionally left blank.
  • Page 3 This chapter describes how to set up the server and Emulex Converged Network Adapter card driver when connecting the ETERNUS DX storage systems to the server via Emulex Converged Network Adapter cards. "Chapter 2 Setup Procedure for QLogic Converged Network Adapter Cards" (page 21) •...
  • Page 4: Table Of Contents

    2.2.4 Installing VMware ESX ............................28 2.2.5 Setting Up the Converged Network Adapter Card Driver..................29 Appendix A WWN Instance Management Table for the Server (Blank) ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 5: Chapter 1 Setup Procedure For Emulex Converged Network Adapter Cards

    Setup Procedure for Emulex Converged Network Adapter Cards This chapter describes how to set up the VMware ESX server and Converged Network Adapter card driver when connecting the ETERNUS DX storage systems to the server via Emulex Converged Network Adapter cards. Workflow...
  • Page 6 • After completing all the required procedures in this manual, proceed to "Checking the LUNs" in "FUJIT- ® SU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware ESX". ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware...
  • Page 7: Setting Up The Converged Network Adapter Cards

    The physical address and WWN of a Converged Network Adapter card are required information in the fol- • lowing cases: when an error has occurred in the system, when using the ETERNUS DX storage systems (host affinity function, etc.) to restrict server access, or when connecting the ETERNUS DX storage systems and the server using a Fibre Channel switch and a CEE/FCoE switch.
  • Page 8 Record the physical address and WWN in the "WWN instance management table for the server". Refer to "Appendix A WWN Instance Management Table for the Server (Blank)" (page 33). ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 9 The WWNs that are obtained in this section may need to be repeatedly regis- tered and set up on the ETERNUS DX until a server recognizes the ETERNUS DX logical disks. For details about ETERNUS DX settings, refer to "FUJITSU Storage ETERNUS DX Configuration Guide - Server Connection- Disk Storage System Settings"...
  • Page 10: Setting Up San Boot

    <PageDn> to Next Page < / > to Highlight, <Enter> to Select ------------------------------------------------------------------------------- Copyright (c) 1997-2009 Emulex. All rights reserved. ------------------------------------------------------------------------------- ==> 1 ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 11 < / > to Highlight, <Enter> to Select ------------------------------------------------------------------------------- Copyright (c) 1997-2009 Emulex. All rights reserved. ------------------------------------------------------------------------------- ===> Enable BIOS is now enabled. ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 12 LUN00 is set and "ETERNUS DX400 series" is used as the device name for the Primary Boot device. ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 13 Input "00" in this example. --------------------------------------------------- DID:xxxxxx WWPN:xxxxxxxx xxxxxxxx Enter two digits of starting LUN (Hex): <ESC> to Previous Menu --------------------------------------------------- ===> 00 -> Enter ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 14 Boot this device via DID <ESC> to Previous Menu < / > to Highlight, <Enter> to Select --------------------------------------------------- ===> Boot this device via WWPN ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 15: Installing Vmware Esx

    Converged Network Adapter card driver should be downloaded and installed from the following URL: • https://my.vmware.com/web/vmware/downloads 1.2.4 Setting Up the Converged Network Adapter Card Driver Change the parameters for the Converged Network Adapter card driver. ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 16 LUNs (Round the result down) Use the value of "8" if the actual result is lower. When the value for this setting is changed, refer to "FUJITSU Storage ETERNUS DX Configuration ® Guide -Server Connection- (FCoE) for VMware ESX"...
  • Page 17 In the following example, the number of ports is "two" since "4" and "5" (two underlined portions) are displayed as the SCSI Host numbers of the Converged Network Adapter card. # ls /proc/scsi/lpfc820 ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 18 LUNs (Round the result down) Use the value of "8" if the actual result is lower. When the value for this setting is changed, refer to "FUJITSU Storage ETERNUS DX Configuration ® Guide -Server Connection- (FCoE) for VMware ESX"...
  • Page 19 Setting value lpfcX_lun_queue_depth Arbitrary (*1) (Up to 512 for each FCoE port of the ETERNUS DX) *1: Recommended value = 512 ¸ (number of FCoE ports that are connected to a single CA port) ¸ number of LUNs (Round the result down) Use the value of "8"...
  • Page 20 Setting Up the Converged Network Adapter Cards Check the setting values. # esxcfg-module -g lpfc820 lpfc820 enabled = 1 options = 'lpfc0_lun_queue_depth=8 lpfc1_lun_queue_depth=8' Reboot VMware ESX. # reboot ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 21: Chapter 2 Setup Procedure For Qlogic Converged Network Adapter Cards

    Chapter 2 Setup Procedure for QLogic Converged Network Adapter Cards This chapter describes how to set up the VMware ESX server and driver when connecting the ETERNUS DX storage systems to the server via QLogic Converged Network Adapter cards. Workflow...
  • Page 22 • After completing all the required procedures in this manual, proceed to "Checking the LUNs" in "FUJIT- ® SU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware ESX". ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware...
  • Page 23: Setting Up The Converged Network Adapter Cards

    The physical address and WWN of a Converged Network Adapter card are required information in the fol- • lowing cases: when an error has occurred in the system, when using the ETERNUS DX storage systems (se- curity function, host affinity function, etc.) to restrict server access, or when connecting the ETERNUS DX storage systems and the server using a Fibre Channel switch and a CEE/FCoE switch.
  • Page 24 Converged Network Adapter Instance name Physical address Cable tag name card WWN slot5 21 00 00 C0 DD 11 A0 21 5800 SERV1_SLOT05 to B8000_1_port05 ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 25 BIOS of the selected card. Select [Select Host Adapter] from the [Fast!UTIL Options] menu and press the [Enter] key. ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 26: Setting Up San Boot

    OS, or the Converged Network Adapter card that is to be used. When using a logical unit (LUN) of the ETERNUS DX storage systems as a boot disk, make sure that the LUN has enough capacity to install the OS.
  • Page 27 QLE8142 5800 QLE8142 5C00 The [Fast!UTIL Options] menu appears. Then perform Step 1 through Step Select [Exit Fast!UTIL] and press the [Enter] key. ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 28: Installing Vmware Esx

    The ETERNUS DX storage systems should appear. If the ETERNUS DX storage systems appear, the settings were performed successfully. If the ETERNUS DX stor- age systems do not appear, recheck the setup procedures given in this manual, the ETERNUSmgr installation and settings, or the Fibre Channel switch and CEE/FCoE switch settings.
  • Page 29: Setting Up The Converged Network Adapter Card Driver

    LUNs (Round the result down) Use the value of "8" if the actual result is lower. When the value for this setting is changed, refer to "FUJITSU Storage ETERNUS DX Configuration ® Guide -Server Connection- (FCoE) for VMware ESX"...
  • Page 30 Setting value ql2xmaxqdepth Arbitrary (*1) (Up to 512 for each FCoE port of the ETERNUS DX) *1: Recommended value = 512 ¸ (number of FCoE ports that are connected to a single CA port) ¸ number of LUNs (Round the result down) Use the value of "8"...
  • Page 31 Chapter 2 Setup Procedure for QLogic Converged Network Adapter Cards Setting Up the Converged Network Adapter Cards When the value for this setting is changed, refer to "FUJITSU Storage ETERNUS DX Configuration ® Guide -Server Connection- (FCoE) for VMware ESX" and change the setting value for the Maximum Outstanding Disk Requests for virtual machines as well.
  • Page 32 LUNs (Round the result down) Use the value of "8" if the actual result is lower. When the value for this setting is changed, refer to "FUJITSU Storage ETERNUS DX Configuration ® Guide -Server Connection- (FCoE) for VMware ESX"...
  • Page 33: Appendix A Wwn Instance Management Table For The Server (Blank)

    This table is used for setting up the Converged Network Adapter cards. Utilize this table if necessary. Host name IP Address Physical slot Converged Network Adapter Instance name Physical address Cable tag name card WWN ® FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware Copyright 2015 FUJITSU LIMITED P3AM-4772-11ENZ0...
  • Page 34 • operational problems as the result of errors, omissions, or the use of information in this manual. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information • in this manual.