Quick Check Maintenance Table - HP Indigo 5000 Preventive Maintenance Manual

All serial numbers
Table of Contents

Advertisement

Quick check maintenance table

Component
General inspection
Config save
Ink unit
ITM drum
PIP drum
CA294-00570
2 Million Imp - Preventive Maintenance Guide - HP Indigo press 5000
Mo
2M
X
Procedure
Check for external dirt, leakage and signs of improper
maintenance. Initiate a service call if there is a leakage problem.
Verify that daily and weekly operator routines have been
performed correctly. See the latest User Guide.
Verify that all lubrication points have been oiled and greased
properly. See the latest User Guide.
Inform your regional manager if the press is not properly
maintained.
Perform Config save to update the customer diskette.
Calibrate the density sensors.
Calibrate the ink conductivity sensors.
Calibrate the ink flow rate.
Clean ITM slip ring (the bias contacts path) using IPA.
Clean the ITM thermostat slip ring.
Verify the temperature sensor reading, and calibrate, if required.
Make sure that the surface facing the IR sensor is clean.
Inspect and thoroughly clean the ITM hood wire mesh filter on
the rear wall using IPA soaked cloth. Caution: Shut down the
press before removing the mesh.
Check the bias carbon brush on the rear wall, and replace, if
required.
Check the ITM overheat thermal fuse carbon brushes on the
front wall, and replace, if required.
Make sure that the housing did not come loose from the press
wall.
Note:
Check the grounding brush, and replace, if required.
Check the condition of the SofSub (PIP underlayer).
See Conditional replacement on page 12.
rev 01
page 8 of 18

Advertisement