Siemens F IWLAN Operating Instructions Manual page 86

Hmi device wireless teach pendant v2
Table of Contents

Advertisement

Operator controls and displays
5.2 LED display
Meaning of the "BAT" LED
The "BAT" LED signals the following states depending on the type of power supply:
Power supply
Rechargeable
battery operation,
HMI device on
Rechargeable
battery operation,
HMI device off
Docking station,
HMI device on or
off
Note the following:
● An error event always has priority.
If an error occurs, the "BAT" LED signals according to column
● If the battery is not fully charged, the "BAT" LED signals according to column
● If the main rechargeable battery is fully charged, the "BAT" LED signals according to
column
86
Charge at ≤6% capacity
Charge at > 6% capacity
Maximum charge
Rechargeable battery not in the HMI device
Rechargeable battery temperature too high
Possible error:
 Short circuit, discharge current > 8.0 A
 Overload, discharge current > 4.0 A
 Overload, charge current > 2.8 A
 Charging error, cell voltage > 4.3 V
 Charging error, cell voltage < 3.0 V
.
BAT LED
Operating Instructions, 08/2010, A5E02453837-01
PRELIMINARY II
1.7.2010
.
.
Wireless Teach Pendant F IWLAN V2