TE8: Cycle-independent path-synchronous switching signal output
16.6 Boundary conditions
Figure 16-5
Suppressing the switching signal output
The user (machine manufacturer) must take appropriate measures, e.g. disable the switching
signal, in order to suppress the activation of the switching signal in the REPOS block in the
constellation described above.
Note
It is the sole responsibility of the user (machine manufacturer) to suppress the output of the
switching signal during repositioning, e.g. after a block search.
References
You will find a description of the block search in:
/FB1/ Function Manual, Basic Functions, Mode Group, Channel, Program Operation, Reset
Response (K1)
16.6.2

Transformations

The function will only run correctly with deactivated transformation. There is no monitoring
function.
A description of the transformations can be found in:
References:
/FB2/ Function Manual, Extended Functions; Kinematic Transformations (M1)
/FB3/ Function Manual for Special Functions, Transformation Package Handling (TE4)
664
Switching signal after block search
Function Manual, 09/2011, 6FC5397-2BP40-2BA0