No.
Name
Transmission
2)
rate setting
switch
Power terminal
3)
block
Communication
4)
terminal block
(Trunk line side)
Table 4.2 Names and settings of parts (2/3)
Set the transmission rate of the module (set to 0 at the time of delivery).
Ensure to set the transmission rate at a speed specified below.
Transmission rate of the trunk line side is identical with that of the
branch line side.
Setting value
0
1
2
3
4
Other than 0 to 4
Connects the module power supply (24V DC) and the ground cable
(FG: Functional Ground).
Terminals are assigned as follows:
Connects the transmission lines on the trunk line side (LINK IN/OUT).
Terminals are assigned as follows:
Application
Transmission rate (bps)
Cannot be set.
If set to other than 0 to 4, the ERR.
LED is turned on and data are not
transferred.
+24V
+24V
24G
24G
NC
NC
FG
FG
FG
FG
DA
DA
DB
DB
DG
DG
SLD
SLD
28
156k
625k
2.5M
5M
10M