Main flowchart (1)...Checking VOL OFFSET
[From Preparation]
Display RST MASK 09 (Pink). / [MKR S09]
Set VOL OFFSET to the tentative setting value minus 50. / [VOF ∗∗∗]
B
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
Display RST MASK 18 (Red 626). / [MKR S18]
Set VOL OFFSET to the tentative setting value plus 56. / [VOF ∗∗∗]
C
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Display RST MASK 19 (Green 626). / [MKR S19]
Is there erroneous discharge (abnormal dead cell)?
D
(Check on the PANEL 1-ADJ menu.)
Display RST MASK 20 (Blue 626). / [MKR S20]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
E
Return VOL OFFSET to the tentative setting value. / [VOF ∗∗∗]
Determine the tentative setting value for VOL OFFSET as
the final value.
[To the Main flowchart (2)]