1
A
Access to 50F DIGITAL Assy
5
Note: The wiring shown in the photo is different from the actual wiring, because the product in the photo is a prototype.
Upon servicing, be sure to restore the original wiring of the unit after repair work.
Note:
When you remove whole Multibase Section, it is not
necessary to remove T panel U Assy.
1
Remove the six screws. (ABA1377)
2
Remove the four screws. (ABA1313)
3
Disconnect the two flexible cables.
B
Note on connection of the flexible cable
This flexible cables requires correct orientation for
connection. Connect the folded side of the cable to the
connector on the DIGITAL Assy, as shown in the photo
below. Reversely connecting the cable will damage
the Assy.
C
D
4
Lift the Multibase Section to the direction of the arrow.
E
F
152
1
2
DIGITAL Assy
Folded side
PDP-5020FD
2
3
1
2
3
3
2
2
1
1
T panel U Assy
4
3
4
1
2
1
1
Multibase Section
50F DIGITAL Assy
4