4.3 Installation

4.3.1 Mounting procedure

4.3.2 Hardware configuration of the DCU

Table 4.1 DCU configurations

4.3.3 Installing an ACU

4.3.4 Installing an extension card

Installation Instructions
8
The DCU can be used as a tabletop or can be mounted on a wall.
To mount a DCU to a wall the following steps have to be carried out:
1. Mark the drill spots on the wall. Use the bracket as drawing mould.
2. Drill 4 holes of 6 mm on the marked drill spots.
3. Place the plugs in the holes.
4. Mount the bracket to the wall using four screws.
5. Place the DCU on the bracket.
The hardware configuration of the DCU depends on the number of handsets and base
stations that are used in the system.
DCU configuration
1 DCU
1 DCU + extension card
2 DCUs (linked system)
2 DCUs (linked system) +
1 extension card
2 DCUs (linked system) +
2 extension cards
The DCU must be equipped with at least one and maximum 8 ACUs to communicate
with the PABX.
For information about how to install an ACU see chapter 6.
The DCU can be equipped with an extension card to connect 8 extra base stations.
For information about how to install an extension card see chapter 8.
Maximum number
Maximum number
of base stations
of ACUs
8
8
16
8
16
16
24
16
32
16
DECT6000