Power Over Ethernet (PoE) Operation for the Series 5300xl Switches

PoE Event Log Messages

PoE operation generates these Event Log messages. You can also configure
the switch to send these messages to a configured debug destination (terminal
device or SyslogD server).
"Informational" PoE Event-Log Messages
I <
> <
MM/DD/YY
HH:MM:SS
Message header, with severity, date, system time, and system
module type (chassis or ports). For more information on
Event Log operation, including severity indicators, refer to
"Using the Event Log To Identify Problem Sources" on page C-27.
Slot < slot-id > Ext Power Supply connected, supplying
< actual-power > W of < avail-power > W max.
The switch detected an EPS (External Power Supply) on the
indicated slot and began receiving the wattage indicated by
< actual-power >. The < avail-power > field indicates the maximum
power (wattage) the detected EPS is capable of delivering.
Slot < slot-id > Ext Power Supply disconnected
The indicated slot has lost contact with an external power supply.
Slot < slot-id > POE usage is below configured threshold
of < 1 - 99 > %
Indicates that POE usage on the module in the indicated slot has
decreased below the threshold specified by the last execution of
the power threshold command affecting that module. This message
occurs if, after the last reboot, the PoE demand on the module
exceeded the power threshold and then later dropped below the
threshold value.
port < port-id > applying power to PD.
A PoE device is connected to the indicated port and receiving
power.
port < port-id > PD detected.
The switch has detected a PoE device connected to the indicated
port.
> <chassis|ports>: