Download Print this page

Philips HB 581/A Service Manual

Solarium sunstudio combi

Advertisement

Quick Links

Service
Service
Service
!
!
Service
Service
Information
Information
Domestic Appliances and Personal Care
GENERAL
The full-body solarium HB 581/A is equipped with a
30 minute timer.
After the pre-set tanning time, the appliance
automatically switches off.
The facial tanner (HP 400 lamps) can be switched on
in two steps (180/260W) by means of switch
SK 1/SK 2.
After the facial tanner has been switched off, it
can only be switched on again after the lamp has
cooled down for 3 minutes!
It has eleven fans - six in the canopy and four in the
couch and one in the control unit - for adequate cooling
of the equipment during operation and two fans for body
cooling.
If malfunctions occur, thermal switch (SK7/SK9/SK11)
will prevent the temperature from rising to an
unacceptable level.
The power supply will only be switched on via the
relays (Re1/Re2) after the timer has been set.
When choosing a place for the appliance, make sure
there is enough free space around the appliance to
guarantee proper cooling.
This solarium has to be connected to 3-phase mains.
Published by Philips Domestic Appliances and Personal Care
4322 277 00344
99/11 - 00/10
TECHNICAL DATA
Operating voltage
Power consumption
Ballast canopy
Ballast couch
Ballast power unit
Starter canopy
Starter couch
Lamp canopy
Lamp couch
Timer
Safety class
Test mark
Length of mains cord
Irradiation field
Dimensions
©
Printed in The Netherlands
Copyright reserved
Solarium
HB 581/A
SUNSTUDIO
COMBI
SAP coding HB 581
: 3 x 230V, 50Hz
: approx. 4250W
: 3 x 100W
: 6 x 80W
: 14 x 100W
: 16 x 80W
: 16 x S12
: 3 x MagneTek ZG 4,5D
: 14 x S12
: 16 x Cleo Performance 80W
: 3 x HP 400
: 14 x Cleo Performance 100W
: 30 min.
: double insulation
: CE
: approx. 3m
: approx. 185 x 80 cm
: approx. 208 x 101 x 91 cm
( L x W x H )
Subject to modification

Advertisement

loading

Summary of Contents for Philips HB 581/A

  • Page 1 Information Information Domestic Appliances and Personal Care SAP coding HB 581 GENERAL TECHNICAL DATA The full-body solarium HB 581/A is equipped with a Operating voltage : 3 x 230V, 50Hz 30 minute timer. Power consumption : approx. 4250W After the pre-set tanning time, the appliance...
  • Page 2 DISASSEMBLY Now all the other parts of the lamp housing of the canopy are accessible and can be disassembled. Before the HP 400 lamps can be taken out, the Canopy reflector (58) and the filter unit (59) have to be loosened and removed.
  • Page 3 Pull the ornamental/retaining strips (3) of the acry- lic sheet (10) up and snap them out. Lift the acrylic sheet off the couch to gain access to the TL’s (2), and YELLOW starters (18). GREEN To replace the remote control WHITE (33), unsolder con- BROWN...
  • Page 4 • If one or more TL’s have broken down, you can • New HP400 lamps may show colour track down the failure cause by exchanging differences. parts (ballasts, starters, lamps). This is not a defect, but a characteristic If these parts are OK, the wiring must be phenomenon of lamps of this type.
  • Page 5 IRRADIANCE With regard to the minimum irradiation indicated The measuring data indicated below were below, you should bear in mind that this is not an established with help of an UVX 36 meter and absolute value at which the lamps must be may only be checked with this equipment, since replaced.
  • Page 6 1 9965 000 01958 housing + cover hinge 40 9965 000 01953 end cover canopy R 2 4822 134 30014 tl Cleo Performance 100W 41 = 2 3 9965 000 01944 locking strip 42 4822 134 80191 tl Cleo Performance 80W 4 9965 000 01945 side cover back couch 43 9965 000 01943...
  • Page 7 HB 581/A 80 Watt 100 Watt 21 22 25 26 31 32...
  • Page 8 58 59 reflector diagram canopy couch...
  • Page 9: Control Unit

    Control unit external switch contact µP La10 La11 La12 La13 Remote control La14 La15 La16...
  • Page 10 Canopy Couch L31a La17 L31b La31 L31c La18 La19 La20 L32a La21 L32b La32 La22 L32c La23 SK10 La24 L33a La10 La25 L33b La33 La11 La26 L33c SK11 La12 La27 SK12 La13 La28 La14 La29 La15 La30 La16 Body cooler...
  • Page 11 Sun-Studio HB581 L32b La 31 La 32 SK10 SK11 La 33 SK12 L32c 16 15 14 13 12 11 10 9 8 7 6 control unit control unit L1...
  • Page 12 La/S HB581 Canopy L32a L31c L31b L31a 100W 100W body-cooler L33c L33b L33a 100W 2 11 10 9 8 7 6 5 4 3 2 1 unit L1...
  • Page 13 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W Couch HB 580/81...
  • Page 14 La/S 100W 100W 100W 100W 100W 100W control unit...
  • Page 15 control unit HB 581...
  • Page 16 R S T N couch canopy TLs canopy R" Power print remote control external switch contact R" suppression capacitor...