Field data of ISO transponders (MDS E)

The limit distances (S
transmission window for each reader-transponder combination are listed in the tables below.
Observe the following information for field data of ISO transponders:
● A maximum median deviation of ±2 mm is possible in static mode (without affecting the
field data).
● In dynamic mode, make sure that rectangular transponders cross the antenna field in the
longitudinal direction.
Note
Relenace of the MDS E transponders
The MDS E transponders are products that will be discontinued. These are relevant for
migration projects in which existing RFID systems are replaced by SIMATIC RF300.
Table 4- 18
MDS E600
MDS E611
MDS E624
All values are in mm
The values relate to the RF310R reader as of version "D".
Table 4- 19
MDS E600
MDS E611
MDS E624
All values are in mm
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
) and operating distances (S
g
Field data RF310R reader
Length of the transmission
window (L)
40
40
30
Field data RF340R reader
Length of the transmission
window (L)
90
90
60
4.2 Field data for transponders, readers and antennas
) along with the length of the
a
Operating distance (S
a
2...93
2...93
2...64
Operating distance (S
a
5...110
20...50
2...60
Planning the RF300 system
)
Limit distance (S
105
105
72
)
Limit distance (S
140
70
75
)