Readers
5.6 SIMATIC RF380R
5.6.6
Metal-free area
The RF380R can be flush-mounted in metal. Please allow for a possible reduction in the field
data values.
Figure 5-23
To avoid any impact on the field data, the distance a should be ≥ 20 mm.
5.6.7
Minimum distance between RF380R readers
RF380R side by side
D ≥ 400 mm (with 2 readers)
D ≥ 500 mm (with more than 2 readers)
Figure 5-24