Page 1
___________________ SIMATIC IPC547E Preface ___________________ Overview ___________________ Safety instructions SIMATIC ___________________ Installing and connecting the device Industrial PC ___________________ SIMATIC IPC547E Commissioning the device ___________________ Monitoring functions of the device Operating Instructions ___________________ Expanding and assigning parameters to the device...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
General knowledge in the field automation control engineering is recommended. Validity of the Operating Instructions These operating instructions are valid for all supplied versions of the SIMATIC IPC547E. Scope of this documentation The documentation for the SIMATIC IPC547E includes the following sections: ●...
DVD burner drive ......................... 45 4.4.2 System with two drives ........................ 46 4.4.3 RAID system ..........................46 4.4.3.1 RAID1 system ..........................46 4.4.3.2 RAID5 system ..........................47 4.4.3.3 RAID system with hot spare drive ....................47 SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 6
Removing module of the redundant power supply ..............79 7.4.6 Removing the enclosure of the redundant power supply from the module ........ 80 7.4.7 Removing the motherboard......................80 7.4.8 Replacing the processor ......................82 SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 7
Technical support ..........................119 Service and support ........................119 Troubleshooting ......................... 120 A.2.1 General information ........................120 A.2.2 RAID system and device startup ....................121 A.2.3 Notes on the use of third-party modules ..................122 SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 8
Table of contents List of abbreviations ..........................123 Glossary .............................. 127 Index ..............................133 SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Overview Product description The SIMATIC IPC547E is a powerful industrial PC in 19" rack format design (4 HE). It is perfectly suited for high-performance industrial PC applications. ● Maximum performance ● Attractive price Applications areas The SIMATIC IPC offers system integrators, cabinet designers, system engineers and machine designers a 19"...
Page 10
● RAID1 – Disk mirroring on two drives, "hot swap" in connection with SATA removable drive bays ● RAID5 – Striping with parity on three drives, "hot swap" in connection with SATA removable drive bays ● Redundant power supply SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 11
Monitoring functions for program execution • Monitoring time can be parameterized in software • Restart can be parameterized in the event of a fault • Warnings can be analyzed by application program (local, via • LAN) SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 12
You will find the languages that can be installed on the Recovery DVD. Language Microsoft Windows 7 Microsoft Windows Server Ultimate 2008 R2 German English French Italian Spanish Japanese Chinese Hong Kong Chinese (simplified) Chinese Taiwan Russian SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
For removable drive bays with drives (HDD or SSD) or for 5.25" drives ⑦ 1 to 4 removable drive bays Depending on configuration, 1 to 4 removable drive bays with drives (HDD or SSD) SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Connection for microphone, 3.5 mm phono jack ⑬ Dual-head graphics card DMS59 connection of optional dual-head graphics card The Ethernet interfaces are numbered on the enclosure to identify them clearly. The numbering by the operating system may deviate from this. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 16
DMS59 connector DMS59 connection ⑮ DVI-I connector DVI-I connections ⑯ VGA connector VGA connections Power supply connections The following figure shows the connections for the power supply for devices with single or redundant power supply. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
The alarm reset button is only available on devices with a redundant power supply. ① On/Off switch ② Alarm reset button can be used to switch off the warning signal SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 18
The On/off button is located on the front of the device behind the front door and is used to start and shut down the operating system. Additional information is available in the sections "Switching on the device (Page 41)" and "Switching off the device (Page 43)". SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
The faulty drive could not be localized by the monitoring software. It may be possible to determine the defective drive with the RAID software, see section "RAID1 system (Page 46)" or "RAID5 system (Page 47)". SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 20
Power supply module is operating. If there is no redundancy, you will hear an acoustic signal permanently. Redundancy is in effect when both power supply modules are operating. Not lit: • Power supply module is out of service. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
When you open the control cabinet, some areas or components may be carrying life- threatening voltages. If you touch these areas or components, you may be killed by electric shock. Switch off the power supply to the cabinet before opening it. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 22
• Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and protect from direct sunlight, moisture and condensation. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
ESD guideline (Page 95). Security information Siemens provides automation and drive products with industrial security functions that support the secure operation of plants or machines. They are an important component in a holistic industrial security concept. With this in mind, our products undergo continuous development.
Page 24
• If the device has a on/off button, assign the parameters of the function of the on/off button to meet your requirements under Windows. You can find the settings in the "Power Options" menu. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Use in an industrial environment without additional protective measures The device has been designed for use in a normal industrial environment in accordance with IEC 60721-3-3 (pollutant class 3C2 for chemical influences, 3S2 for sand and dust). SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 26
Safety instructions 2.3 Notes on use SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
The device may be damaged. Do not dispose of the original packaging. Pack the device during transportation and storage. 5. Check the contents of the packaging and any accessories you may have ordered for completeness and damage. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 28
7. Please keep the enclosed documentation in a safe place. It belongs to the device. You need the documentation when you commission the device for the first time. 8. Write down the identification data of the device. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
● COA label The COA label (Certificate of Authenticity) is located inside the front door and is only attached with pre-installed Windows operating systems. ● Component label The component label is located inside the front door. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
(EN 60950-1:2006 and DIN EN 60950-1:2006-11) become void. Overheating can cause a fire. Proper functioning of the device is no longer guaranteed. Before you install the device, note the following general installation information. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
You can order a Tower Kit for tower installation. ● Mounting on telescopic rails When telescopic rails are used for mounting, the device can be withdrawn fully from the cabinet or rack. Note the information in section "Telescopic rails (Page 107)". SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 32
For 600 mm cabinet: Threaded holes for type 3659.180 telescopic rails from the Rittal company For 800 mm cabinet: Threaded holes for type 3659.190 telescopic rails from the Rittal company ② Threaded holes for type 20110-072 telescopic rails from the Schroff company SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Ensure that the power outlet or shockproof power outlet of the building installation is freely accessible and as close as possible to the device, especially if the power plug is secured by a power plug latch. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Hot-plug I/O devices (USB) may be connected while the PC is in operation. NOTICE Non-hot-plug I/O devices I/O devices that do not support hot-plugging may not be connected until the device is powered off. Strictly adhere to the specifications for peripheral equipment. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
The equipotential bonding connection on a device has a large surface and makes contact over a large area. The equipotential bonding connection is identified by the following symbol: Requirement ● T20 screwdriver SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are identified with the classification "VFI-SS-.." or "VI-SS-..". Note The power supply of the device contains a PFC (Power Factor Correction) circuit to conform to the EMC directive. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 37
Use a flexible cable with UL approval and CSA marking as well as the following features: ● Type SJT with three conductors ● Conductor cross-section ≥ 18 AWG ● Cable length ≤ 4.5 m ● Tandem grounding-type plug 15 A, ≥ 250 V SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 38
4. Switch on the on/off switch To prevent unintentional removal of the power cable, you can secure the plug as follows: ① 1. Remove the retaining screw ② 2. Screw on the latch for the power plug SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 39
To prevent unintentional removal of the power cable, you can secure the power plug as follows: ① 1. Remove the retaining screws ② 2. Screw on the latch for the power plug SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
You can operate up to five monitors simultaneously at the interfaces of the integrated graphics controller in combination with the optional graphics card. Parameter assignment is performed by means of the Control Panel in Windows. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
1. Switch the on/off switch to position I. Information on the position of the switch is available in the section "Operator controls (Page 17)". 2. Press the on/off button. The"POWER" LED lights up. The module carries out a self-test. Then Windows is started. 3. Follow the instructions on the screen. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
20 seconds. Automatic startup may endanger the operation of the machine or plant, for example, after a power failure. Take the BIOS Setup entry "Power Failure Recovery" into consideration in the plant planning. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
For non-Windows operating systems: ● Briefly press the on/off button. The operating system is shut down. The "POWER" LED goes out. The device is switched off but not fully disconnected from the mains voltage. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 44
Data on the drive may be lost. The device may be damaged. Perform a hardware reset only in the case of an emergency. For all operating systems: ● Press the on/off button for more than 4 seconds. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Data comparison is the only guarantee that data has been written correctly. Perform data comparison each time you burn a disc. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
For information on the mounting positions, refer to section "Replacing a defective hard disk drive in the RAID system (Page 70)". Additional information on RAID1 systems can be found in the section "Managing RAID systems (Page 57)." SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
"Replacing a defective hard disk drive in the RAID system (Page 70)". ● Information on integration of a replaced hot spare drive into the RAID system is available in the section "Integrating a hot spare hard disk drive in the RAID system (Page 62)". SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 48
Commissioning the device 4.4 Information on optional features SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
The SIMATIC IPC DiagMonitor software offers additional alarm and linking options in addition to the local monitoring functions of the SIMATIC IPC DiagBase software and includes: ● The software for the stations to be monitored. ● A library for creating user-specific applications. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
The operation of the front, CPU and power supply fans is monitored. If a fan fails, the following reactions are triggered: ● The "FAN" status display lights up red. ● If the SIMATIC monitoring software is installed, a fan alarm is output. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
The "Reset on" option immediately triggers a hardware reset that may result in loss of data under Windows. WD monitoring times The monitoring time can be configured with the DiagBase or DiagMonitor software. Note When you change the monitoring time, the change becomes effective immediately. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
The warranty does not cover a reset of the hardware in the event of a loss of a password. Please store the password carefully and make sure it is protected against unauthorized access. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
● The front door is open. Procedure 1. Press the marked hooks at the same time to release the front panel. 2. Swivel the front panel in the direction indicated and lift it off. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Limitation of liability All technical specifications and approvals apply only to expansions which are approved by the Siemens AG. We are not liable for functional limitations caused by the use of third-party devices or components. Observe the installation instructions for the components. UL approval of the device only applies when UL-approved components are used according to their "Conditions of...
If the height is exceeded, you may experience contact problems, malfunctions and difficulties with the assembly. You can find the permitted dimensions for expansion cards in the chapter "Dimensional drawing for the installation of expansion cards (Page 99)". SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 56
7. Secure the card retainer with the screw If you are installing a short expansion card, remove the locking screw from the card retainer and install it in the opposite hole. 8. Close the device. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Device maintenance and repair Managing RAID systems 7.1.1 Example for a RAID1 system during the boot phase of the system 7.1.2 Example for a RAID5 system during the boot phase of the system SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
1. Select the RAID software via "Start > Programs > Intel Rapid Storage Technology". 2. Select "Manage" > "Advanced" to display details about the RAID1 system. 3. Select the "Help > "System Report" > "Save" command to create a report with details about the RAID1 system. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
The functioning hard disk is indicated by BIOS with its port number or by the RAID software with its device port number. The following figure shows the corresponding window in the RAID software with a RAID1 system. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
To be able to boot from the RAID system (RAID1 or RAID5), you must place it first in the list of bootable sources in the BIOS "Boot" setup menu. Otherwise, the system will boot from the hard disk drive you have just installed and the message "Operating system not found" will be displayed. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Pressing the "Rebuild to another Disk" link initiates synchronization of the RAID system (RAID1 or RAID5). A defective hard disk drive is still displayed during the rebuilding process. This display disappears when the rebuilding process is completed. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Drives 3 years Backup battery 5 years Device fan 3 years Filter pad Depending on the degree of soiling Information on ordering replacement parts is available in the chapter "Service and support (Page 119)". SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
RF suppression. Contact your technical support team or where you purchased your PC to find out which system expansion devices may be installed. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 64
● T20 screwdriver for protective conductor connection and enclosure ● T6 screwdriver for removing and installing the DVD drive ● T10 screwdriver for all of the remaining screws See also Spare parts and repairs (http://support.automation.siemens.com/WW/view/en/16611927) SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
● The device is open, see the section "Open the device (Page 54)". ● The front door is open, see chapter "Opening the front door (Page 53)". Procedure Removal 1. Remove the highlighted screws. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 66
3. Hold the drive cage using the highlighted areas, move it in the direction of the arrow and lift it out completely from the device. Installation Follow the steps described under removal in the reverse order. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
2. Use the appropriate key to unlock the tray on the removable drive bay. 3. Open the handle on the removable drive bay and open it at the highlighted spot in direction of the arrow until you feel a slight resistance. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 68
Make sure that the tray is completely inserted into the removable drive bay. 5. Close the handle and lock the tray. Note The tray must always be locked in the removable drive bay to ensure reliable operation of the devices with removable drive bays. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
● The device is fully disconnected from the mains voltage, see chapter "Switching off the device (Page 43)". ● The device is open, see the section "Open the device (Page 54)". ● T10 screwdriver SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Replace the drive in the removable drive bay when the "HDD" status display of the device is not lit. Observe the ESD guideline (Page 95). Always replace the drive with a new drive of the same type and capacity. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 71
The following tables include information on the alarms of the status displays. If the hard disk drive is defective and the SIMATIC monitoring software is installed, the LEDs of the status display light up individually or simultaneously. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 72
① Removable drive bay 0 ② Removable drive bay 1 ③ Removable drive bay 2 ④ Removable drive bay 3 ⑤ "Power" LED; power supply available ⑥ "HDD" LED, access to hard disk drive SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
● The device is fully disconnected from the mains voltage, see chapter "Switching off the device (Page 43)". ● The drive cage has been removed, see chapter "Removing and installing the drive cage (Page 65)". ● T10 screwdriver SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 74
The following figure shows the possible positions of the screws on the right side of the drive cage. 4. Install the drive cage back into the device, see section "Removing and installing the drive cage (Page 65)". SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
The following figure shows the positions of the screws on the fan side of the drive cage. The following figure shows the positions of the screws on the drive cage on the outside of the device. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
● The front panel is removed, see section "Removing the front panel (Page 53)". ● The device is open, see the section "Open the device (Page 54)". ● T20 screwdriver ● A fan Use only a fan of the same type. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 77
Two small arrows are shown on the device fan. These indicate the rotating direction of the fan and the direction of the airflow. Install the fan in such a way that the arrow for the direction of the airflow points to the interior of the enclosure. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
● An identical lithium battery or a type recommended by the manufacturer Information on original spare parts for SIMATIC IPCs is available at SIMATIC IPC after- sales information system (http://www.siemens.com/asis). Procedure 1. The location of the backup battery on the motherboard and the procedure for replacing it are described in the manual of the motherboard on the supplied "Documentation and...
● The device is fully disconnected from the mains voltage, see chapter "Switching off the device (Page 43)". ● T10 screwdriver Procedure 1. Remove the screws highlighted in the first figure. 2. Pull out the power supply module from the enclosure using the handle. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
(Page 43)". ● The device is open, see the section "Open the device (Page 54)". ● A motherboard The motherboard as spare part is supplied without processor and memory modules. ● T10 screwdriver SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 81
1. For installation, follow the steps for removal in reverse order. 2. Update the BIOS to match the version of the motherboard. Note during the update if you are operating a device with or without RAID system. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Only an approved processor is permitted to be installed on the motherboard of the device. Information about original spare parts for SIMATIC IPCs is available on the Internet at: – SIMATIC IPC after-sales information system (http://www.siemens.com/asis) – Contacts (http://www.siemens.com/automation/partner) ● Manual of the motherboard on the supplied "Documentation and Drivers" DVD.
Page 83
If the installed processor is operated with a higher clock frequency than permitted, it can be destroyed or cause loss of data. Operate the processor only at a clock frequency that is equal to or less than the permitted clock frequency. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Note Before you install new drivers or operating system updates for Windows MUI versions, configure the regional menu and dialog settings and the default English (US) language. Other operating systems Contact the corresponding manufacturer. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Installing the software ● You can find information about installing SIMATIC software packages in the corresponding documentation. ● You can obtain information about driver updates and installing application programs from the respective manufacturers. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Press any key to boot from CD or DVD .. After a few seconds, you will see the "Install Windows" installation program. 8. Now follow the instructions in the installation program. You can find additional information on this in the next section. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 87
Please read the information in the section "Information for systems with RAID or AHCI controller". Drive options For display of additional functions that you can use to set up the data medium, (advanced) see figure "Windows installation window "Drive options (advanced)"". SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 88
Integrate this driver before you partition the data medium and before you install the operating system. For more information on integrating the storage controller, refer to the section "Information for systems with RAID or AHCI controller". SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
For this purpose, you can either select one of the preinstalled languages or install a new language package. The following command sequences are described in English. Depending on the default setting, they can be displayed in another language. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 90
1. Choose: "Start > Control Panel > Clock, Language, and Region > Regional and Language Options" 2. Select the "Keyboards and Languages" tab. 3. Click the "Install/uninstall languages" button and make the required changes. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
All data on drive C: will be completely deleted, reformatted and overwritten with the original factory software. If "Restore entire drive" is set ALL data, user settings, authorizations or license keys will be lost on the entire drive. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
(images). SIMATIC IPC Image & Partition Creator supports the burning of DVD media only. You can order the tool using the Siemens online ordering system (http://www.siemens.com/automation/mall). For more information about SIMATIC IPC Image & Partition Creator, refer to its product documentation.
If the device is supplied with installed software, observe the corresponding license agreement. UL approval The following approvals are available for the device: ● Underwriters Laboratories to Standard-UL 60950-1, File no. E11 5352 ● Canadian National Standard CAN/CSA-C22.2 No. 60950-1-07 (I.T.E) SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 94
This product meets the requirements of Korean certification. This product satisfies the requirement of the Korean Certification (KC Mark). 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Directive". Compliance with this standard has been verified according to EN 60950-1:2006 + A11:2009 +A1:2010 +A12:2011. 8.2.3 Declaration of conformity The corresponding documentation is available on the Internet at: SIEMENS Industry Online Support (http://support.automation.siemens.com/WW/view/en/10805661/130000). Navigate to your device in the left display area in the tree structure under "Industrial PC". 8.2.4...
Page 96
These values conform to the specifications of IEC 61000-4-2. ① Synthetic materials ② Wool ③ Antistatic materials such as wood or concrete SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 97
This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Technical specifications 8.3 Dimension drawings Dimension drawings 8.3.1 Dimension drawing of the device Front view and plan view SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Technical specifications 8.3 Dimension drawings 8.3.2 Dimensional drawing for the installation of expansion cards 8.3.3 Dimension drawing for the drilling holes of telescopic rails SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Current delivery (DC) +5 V/26 A, +3.3 V/24 A; in total 190 W permitted +12 V/15 A; +12 V/15 A; –12 V/0.2 A; +5 Vaux/2 A The total sum of all voltages is max. 230 W. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 101
1 V/m, 2 to 2.7 GHz • 80% AM to IEC 61000-4-3 10 V, 150 kHz to 80 MHz • 80% AM to IEC 61000-4-6 Magnetic field 30 A/m, 50 Hz/60 Hz (to IEC 61000-4-8) SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 102
When using a hard disk drive in a removable drive bay, the device should generally be free of mechanical disturbances. When using a DVD burner, the device should generally be free of mechanical disturbances during burning. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 103
12 V; 2.1 A • 3.3 V ; 0.4 A • Power consumption per slot, permitted ≤ 25 W Power loss all slots, permitted ≤ 80 W Total 3.3 V current may not exceed 1.2 A. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 104
DisplayPort 2560 × 1600 at 60 Hz, 32 bit color depth – DVI 1920 × 1200 at 60 Hz, 32 bit color depth – VGA 2048 × 1536 at 60 Hz, 32 bit color depth Adapter for VGA and DVI-D supplied SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 105
Switch Fault Tolerance (SFT) • Audio Realtek ALC671, 6-channel DAC support Micro • Line In • 2 W at 4 Ω Line Out • AMT and teaming cannot be used simultaneously on the Ethernet interface. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
+5 V 2.5 A + 5%, – 3% The total output of the +5 V and +3.3 V voltage must be ≤ 190 W. The inrush current is: ● ≤ 80 A for 3.6 ms SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
M5 x 6 mm The mounting screws of the telescopic rails may not protrude by more than 5 mm into the enclosure. See also Dimension drawing for the drilling holes of telescopic rails (Page 99) SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
3. Open the application. 8.5.3 Interrupt assignment Interrupt assignment depending on operating system The functions are assigned different interrupts (IRQ), depending on the operating system. A distinction is made between the PIC and APIC modes. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 109
IRQ A to H is assigned to IRQ 0 to 15 automatically by the BIOS in PIC mode. A specific assignment cannot be forced. Interrupt PIC and APIC mode Interrupt APIC mode BIOS Default Interrupt PIC mode, e.g. DOS SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 110
PCI-IRQ A to H is assigned to IRQ 0 to 15 automatically by the BIOS in PIC mode. A specific assignment cannot be forced. Interrupt APIC mode BIOS Default Interrupt PIC mode, e.g. DOS SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Drivers" DVD that ships with the manual. Note After a BIOS update, you need to execute the "Restore Defaults" command. Executing the "Restore Defaults" command restores all BIOS settings to their original state. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
An ISO file contains a memory image of the content of a CD or DVD structured in the ISO 9660 format. ● Remote reboot An AMT PC can be booted remotely from a bootable ISO file made available by another SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 113
SIMATIC IPC Remote Manager The "SIMATIC IPC Remote Manager" software is available for utilization of the AMT functions with SIMATIC IPCs. The software can be ordered from the Siemens online ordering system "Industry Mall (http://mall.automation.siemens.com)". For detailed information about "SIMATIC IPC Remote Manager", refer to the corresponding product documentation.
BIOS setup. Afterwards the Intel Management Engine (Intel ME) has to be activated ® ® and set for AMT. Set the following in the Management Engine: ● Configure network for access via AMT ● Create password SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
5. Exit the BIOS with the <F10> key "Save and Exit". The AMT PC starts. 6. To access the MEBx, press the <Ctrl+P> keyboard shortcut at system power-up. 7. In the login dialog, enter the standard password "admin". SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
<Fully qualified domain name>:16993" and for unencrypted connections "http://<IP address>:16992". ● WinRM: A command line program that is part of Windows as of Windows Vista. This tool can be downloaded for older Windows versions. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
3. After the start, a user prompt appears asking whether you really want to discard all the settings in the Management Engine. 4. Confirm with "Y". On a German keyboard, this means pressing the <Z> key. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
2. Select the value "KVM" for "User Consent". To allow a user with administrator privileges to avoid this code query, follow these steps: 1. Select "Intel(R) AMT Configuration > User Consent" in the MEBx. 2. Enable "Opt-in configurable from remote IT". SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (http://www.siemens.de/automation/csi_en_WW) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa-db/en/Pages/default.aspx) ●...
BIOS Setup. 2. Set the time and date in the setup menu. Although the BIOS setting is The backup battery is dead. Replace the backup battery. OK, the time and data are still wrong SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
After changing the drive, System was booted without Reboot the system with a functioning drive. "unused" is indicated for the functioning drive. The relevant SATA port removable drive bay might not be switched on. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Different pin assignment • module being used was the cause of the fault. Replace the thrid-party module with a Siemens module or contact the module supplier. If the device still crashes, contact your technical support team. Insufficient output of an external Use a higher capacity power supply power supply, e.g., UPS...
Page 123
Operating system without GUI Digital Versatile Disk Digital versatile disk Digital Visual Interface Digital display interface DVI-I Digital Visual Interface Digital display interface with digital and VGA signals Extended capability port Extended parallel port SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 124
Programmable interrupt controller Preboot Execution Environment Software for running new PCs without drive data via the network RAID Redundant Array of Independent Disks Redundant drive array Random Access Memory Read-Only Memory SDRAM Synchronous DRAM SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 125
German Electrical Engineers) Video Graphics Array Video adapter which meets industrial standard Virtualization Technology Intel technology with which a virtually closed environment can be made available Watchdog Program monitoring with error detection and alarming SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 126
List of abbreviations SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Located on the motherboard, connects the processor with the RAM, the graphics controller, the PCI bus, and the external interfaces. Configuration files These are files containing data which define the configuration after restart. Examples of such files are CONFIG.SYS, AUTOEXEC.BAT and the registry files . SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 128
This can be configured in Windows by selecting Settings > Control Panel > Energy options. Ethernet Local network (bus structure) for text and data communication with a transfer rate of 10/100/1000 Mbps. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 129
The devices connected to a LAN are called nodes. The purpose of networks is the mutual use of files, ers or other resources. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 130
Glossary License key The license key represents the electronic license stamp of a license. Siemens provides the license keys for protected software. Module Modules are plug-in units for PLCs, programming devices or PCs. They are available as central modules, interface modules, expansion cards or mass storage (mass storage module).
Page 131
300 Mbps. Session-At-Once In session-at-once, the CD can be written to both with an audio session and a data session. The two sessions are written to at once (as in disc-at-once). SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 132
In track-at-once recording, a CD can be written to in bits in several sessions if the CD was not closed. Wake on LAN Wake on Local area network. This function allows the PC to be started via the LAN interface. SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
COA label, 29 Technical specifications, 104 COM1 Types and mounting locations, 11 Connection, 15 Dust protection, 101 COM1 port DVD drive Technical specifications, 105 Removing and installing, 75 COM2 DVI-I Connection, 15 Connection, 15, 16 SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 134
68 LEDs, (Status displays) remove from drive bay, 67 License key, 91 Second hard disk drive, (See System with two Limitation of liability, 64 drives) Hardware reset, 44 Connection, 15 LPT1, 105 SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 135
Removing, 27 Status displays of the hard disk drives, 73 Power consumption, 100 RAID5 system with hot spare drive, 47 Power plug latch, 38, 39 Rating plate, 29 Power requirements, 106 Real-time protection, 43 SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...
Page 136
Disconnect from mains voltage, 44 Forced shutdown, (Hardware reset) Hardware reset, 44 Shutting down the operating system, 43 Switching on the device Configure automatic startup, 42 Switching on for the first time, 41 System partition, 91 SIMATIC IPC547E Operating Instructions, 09/2013, A5E32317120-AA...