Power Failure Ports - Panasonic KX-NS1000 Installation Manual

Pure ip-pbx
Hide thumbs Also See for KX-NS1000:
Table of Contents

Advertisement

4.12 Power Failure Ports

When the power supply to the PBX fails, power failure transfer (PFT) will switch from the current connection
to the Power Failure Connection. Refer to "15.1.8 Power Failure Transfer" in the Feature Manual for further
information.
For information about PFT for stacked PBXs, refer to the Installation Manual for each PBX.
Using SLC2/LCOT2 Card
In the event of a power failure, a specific SLT is automatically supplied power through the PFT port. The PFT
ports are the SLC1 port and LCOT1 port on the SLC2/LCOT2 card.
Note
A CO line conversation established during power failure can be maintained even when the power returns
and the connection is switched back to the normal configuration from the Power Failure Connection.
Document Version 2016-03
4.12 Power Failure Ports
Installation Manual
167

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents