Hitachi IJ RX2 Service Manual page 201

Hide thumbs Also See for IJ RX2:
Table of Contents

Advertisement

6.2.22 Viscometer Ink Temperature Sensor Fault
Viscometer Ink
Temperature Sensor
Fault
Disconnect and reconnect the following
connectors.
▪ EZJ126: CN13
▪ EZJ132: CN1, 3
▪ Thermistor relay harness connector
Does the fault recur?
Replace the thermistor.
Does the fault recur?
Replace the EZJ126 board.
6.2.23 Ink Heating Unit Temperature Low
Ink Heating Unit Temperature Low
Disconnect the EZJ125
board CN7 connector and
reconnect it.
Is the fault issued
again?
Replace the heating unit.
Is the fault issued
again?
Replace the EZJ125 board.
Is the fault issued
again?
Replace the EZJ126 board.
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
6-22
Resume the
.
operation
Resume the
operation.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents