3.27 [1-1] Slot—Card Property - LCO type
3.27 [1-1] Slot—Card Property - LCO type
The properties of the analog CO line cards can be specified.
Outgoing Guard Time
Specifies the length of time after a CO line is disconnected, during which the PBX cannot seize the line.
Default
3 s
Value Range
3–6 s
Maintenance Console Location
3.27 [1-1] Slot—Card Property - LCO type
Programming Manual References
None
Feature Manual References
None
First Dial Timer (CO)
Specifies the minimum time that the PBX waits after seizing a CO line, before sending the dialed digits to the
telephone company. This allows the telephone company to have enough time to accept the dialed digits
correctly.
Default
1.0 s
Value Range
0.5 ´ n (n=1–16) s
Maintenance Console Location
3.27 [1-1] Slot—Card Property - LCO type
Programming Manual References
None
Feature Manual References
None