Chapter 3 Features and Functions
Output Configuration
• When power is turned off, the function generator automatically stores
State Storage
its state in memory location "0". You can configure the function
(continued)
generator to automatically recall the power-down state when power is
restored. The recall mode is disabled when the function generator is
shipped from the factory.
Select the
enable the power-down recall mode. Select
disable the power-down recall mode. See "Power-Down Recall Mode"
on page 109 for more information.
• From the remote interface, you can use memory location "0" to store
a fourth instrument configuration (you cannot store to this memory
location from the front panel). However, keep in mind that memory
location "0" is automatically overwritten when the power is turned off.
• Front-Panel Operation:
To store the state, press
keys, or "Enter Number" mode to select the memory location.
To restore the state, press
or "Enter Number" mode to select the memory location.
• Remote Interface Operation:
• From the remote interface, you can delete individual stored states
and clear the memory location. If nothing is stored in the specified
memory location, a +810, "State has not been stored" error is generated.
70
POWER ON LAST STATE
Shift Store
*SAV {0|1|2|3}
*RCL {0|1|2|3}
MEMory:STATe:DELete {0|1|2|3}
command from the
POWER ON DEFAULT
. Then use the knob, arrow
. Then use the knob, arrow keys,
Recall
State 0 is the instrument state at power down.
States 1, 2, and 3 are user-defined states.
to
SYS MENU
to