Siemens Micromaster 420 Operating Instruction page 73

Hide thumbs Also See for Micromaster 420:
Table of Contents

Advertisement

5. SYSTEM PARAMETERS
Parameter
Number
P1130
Ramp-up initial rounding time
Defines initial smoothing time in seconds as shown on the diagram below.
where
T
total =
up
T
total
down
X is defined as ∆f= x*F
P1131
Ramp-up final rounding time
Defines smoothing time at end of ramp-up as shown in P1130.
P1132
Ramp-down initial rounding time
Defines smoothing time at start of ramp-down as shown in P1130.
P1133
Ramp-down final rounding time
Defines smoothing time at end of ramp-down as shown in P1130.
MICROMASTER 420 Operating Instructions
6SE6400-5AA00-0BP0
Parameter Name
P1130
P1131
½ P1130 + X * P1120 + ½ P1131
=
½ P1132 + X * P1121 + ½ P1133
max
P1132
P1133
International English
♦ ♦ ♦ ♦ P0003 User
Min
Access Level
Max
♦ ♦ ♦ ♦ P0004 Setting
[Default]
♦ ♦ ♦ ♦ Changeable
Units
♦ ♦ ♦ ♦ Status
0
2
40
10
[0]
'•'
s
0
2
40
10
[0]
'•'
s
0
2
40
10
[0]
'•'
s
0
2
40
10
[0]
'•'
s
73

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents