Haier HCW3260AES Installation Instructions Manual page 15

30" single and double built-in oven
Hide thumbs Also See for HCW3260AES:
Table of Contents

Advertisement

Available languages

Available languages

2. Connect the two black wires
3. Connect the two neutral (white) wires
(of the oven cable) using a UL listed wire connector.
4. Connect the two red wires
5. Install junction box cover.
4-WIRE CONNECTION (UNGROUNDED NEUTRAL) - U.S.A. AND
CANADA
4-Wire Cable from Home Power Supply
IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local
codes do not allow grounding through neutral, New Branch circuit installations (1996
NEC), mobile homes and recreational vehicles, new construction and in Canada.
1. Disconnect power.
a
Junction Box
b
Black Wires
c
Red Wires
d
Cable from Oven
2. Connect the 2 black wires
3. Connect the 2 red wires
4. Untwist white wire from green (or bare) ground wire coming from the oven.
5. Connect the 2 neutral (white) wires
6. Connect the ground (green or bare) wire
(green or bare) wire (in the junction box) using a UL listed wire connector.
7. Install junction box cover.
b
together using a UL listed wire connector.
g
together using a UL listed wire connector.
Ungrounded Neutral
a
b
c
d
e
UL listed or CSA
Approved Conduit
Connector
f
Ground (Green or
Bare) Wires
b
together using a UL listed wire connector.
c
together using a UL listed wire connector.
h
c
and the ground (green or bare) wire
i
h
g
f
e
g
UL Listed Wire
Connector
h
Neutral (White) Wires
i
House Electrical Supply
together using a UL listed wire connector.
f
from the oven cable to the ground
d
13