4
Turning Simple Contours
4.2 Turning with path dimension input
4-74
If required, select and overwrite Feed and Speed using the cursor
keys.
e.g.
F
0.25 mm/rev
S
530 rev/min.
Initiate feed motion by pressing the Start key.
The feed motion can be interrupted at any time by means of the Stop
key.
When you switch over between the "Angle", "Radius" and "IK" soft
keys, a value conversion is performed provided that a valid circle is
described by the existing values.
© Siemens AG, 2002. All rights reserved
SINUMERIK 840D/810D Operator's Guide ManualTurn (BAM) – 08.02 Edition
4
08.02