Anti-Tip Block; Electrical Requirements - Bosch HMD8451UC Installation Instructions Manual

Drawer microwave
Hide thumbs Also See for HMD8451UC:
Table of Contents

Advertisement

Available languages

Available languages

Anti-Tip Block

Normal Installation Steps
Anti-Tip Block Installation Instructions
The 6-inch anti-tip wooden block must be provided by
the installer. The anti-tip block reduces the risk of drawer
tipping when installed properly. Install the anti-tip block
13
14
/
inches above the installation opening floor (where
16
the unit will sit) for a standard installation or 14
for a flush installation. See Figure 3 (standard installation)
or Figure 4 (flush installation) and Figure 5.
If the Drawer Microwave is ever moved to a different loca-
tion, the anti-tip block must also be moved and installed.
If the anti-tip block is to be anchored to the wall make cer-
tain that the screws holding it penetrate into the structural
members (studs) behind any covering such as drywall.
The anti-tip block prevents serious injury that might result
from spilled hot liquids.
5"
4"
CAUTION
Make sure that the screws do not contact any
wiring or plumbing that may be present in the wall.
WARNING
The unit can tip and cause spills and potential
burns or other injuries if the anti-tip block is not
installed correctly.
English 9
5
/
8
6"
Anti-Tip
block
3
1
/
"
2
Figure 5

Electrical Requirements

The unit requires a 120 volt, 60 Hz, 15 AMP (minimum)
circuit. It is recommended that the unit be installed on a
separate circuit that serves only this appliance.
This appliance is fitted with a 3-prong grounded electrical
plug. Do not modify the plug or use an adapter. If the plug
does not fit with the available receptacle, have a licensed
electrician install a properly grounded outlet before
proceeding with the installation. The power cord length is
inches
approximately 46".
Installer - show the owner the location of the circuit
breaker or fuse. Mark it for easy reference.
Note: If you have any questions about the grounding or
electrical instructions, consult a qualified electrician.
* Can also be installed using an electrical outlet in an adjacent
cabinet within the area where the provided electrical cord can
reach.
Always check electrical codes for requirements.