Siemens SINAMICS S120 Configuration Manual page 108

1ph4 induction motors
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor components
5.4 Gear
Table 5- 19
Control sequence when selecting the gearbox stage
Gearbox stage selection
On ratio changeover from stage i
a Initial setting (f)
b Selection sequence
c Mechanical selection carried out up to endstop
On ratio changeover from stage i
d Initial setting (c)
e Selection sequence
f Mechanical selection carried out up to endstop
L
Contact closed
0
Contact open
1)
A limit switch (S1 or S2) sends a signal to the control after selection to switch out the selector unit.
108
to i
2
1
1)
to i
1
2
1)
Connector contact No.
2
3
+24 V DC
0 V
0 V
+24 V DC
Configuration Manual, (APH4S), 08/2008, 6SN1197-0AD64-0BP1
4/5 (S1)
5/6 (S2)
0
L
0
0
L
0
L
0
0
0
0
L
1PH4 Induction Motors