The following applies to the
selector gearbox:
Both gearbox ratios are electrically selected and the setting is monitored using limit switches.
The gearbox output lies coaxially to the motor shaft.
Circumferential backlash (measured on gearbox output): 30'
For milling and machining with interrupted cut, the following special versions are available on
request:
● Lower play: Max. 20'
● Lower play for increased requirements: Max. 15'
Belt pulley
● The belt pulley should be in the form of a cup wheel.
● The gearbox output shaft has a flange with outer centering and tapped holes to retain the
● The complete drive should be designed to be as stiff as possible using large belt cross-
5.4.2

Specifications

Table 5- 17
Technical data for gearbox
Type
SH
Order No.
ZF
identifier
2K120
100
2LG4312-...
2K250
132
2LG4315-...
2K300
160
2LG4320-...
1)
2)
1PH4 Induction Motors
Configuration Manual, (APH4S), 08/2008, 6SN1197-0AD64-0BP1
belt pulley.
sections. This has a positive impact on the smooth running properties of the drive.
Maximum
speed
n
max
[rpm]
[Nm]
8000
120
1)
9000
2)
6300
250
8000
2)
6300
300
8000
2)
Higher maximum speed from 8000 ... 9000 rpm for more than 20% load duration is only
possible with injection lubrication.
Permissible with gearbox oil cooling for gearbox stage i = 1.
Switch position I:
Switch position II:
Rated torque
(S1 duty)
Drive
Output
i = 1
i = 4
[Nm]
[Nm]
[Nm]
120
480
140
250
1000
400
300
1200
400
i
= 4
1
i
= 1
2
Maximum torque
(S6 duty,
10 min duty cycle,
max. 60% load duration)
Drive
Output
i = 1
i = 4
[Nm]
[Nm]
140
560
400
1600
400
1600
Motor components
5.4 Gear
Weight
Output
housing
[kg]
[mm]
30
100
62
116
70
140
105