GE B30 UR Series Instruction Manual page 461

Bus differential system
Hide thumbs Also See for B30 UR Series:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 35 of 61)
ADDR
REGISTER NAME
8C52
...Repeated for Digital Element 28
8C68
...Repeated for Digital Element 29
8C7E
...Repeated for Digital Element 30
8C94
...Repeated for Digital Element 31
8CAA
...Repeated for Digital Element 32
8CC0
...Repeated for Digital Element 33
8CD6
...Repeated for Digital Element 34
8CEC
...Repeated for Digital Element 35
8D02
...Repeated for Digital Element 36
8D18
...Repeated for Digital Element 37
8D2E
...Repeated for Digital Element 38
8D44
...Repeated for Digital Element 39
8D5A
...Repeated for Digital Element 40
8D70
...Repeated for Digital Element 41
8D86
...Repeated for Digital Element 42
8D9C
...Repeated for Digital Element 43
8DB2
...Repeated for Digital Element 44
8DC8
...Repeated for Digital Element 45
8DDE
...Repeated for Digital Element 46
8DF4
...Repeated for Digital Element 47
8E0A
...Repeated for Digital Element 48
Trip Bus (Read/Write Setting) (6 modules)
8ED0
Trip Bus 1 Function
8ED1
Trip Bus 1 Block
8ED3
Trip Bus 1 Pickup Delay
8ED4
Trip Bus 1 Reset Delay
8ED5
Trip Bus 1 Input (16 items)
8EF5
Trip Bus 1 Latching
8EF6
Trip Bus 1 Reset
8EF8
Trip Bus 1 Target
8EF9
Trip Bus 1 Events
8EFA
Reserved (8 items)
8F02
...Repeated for Trip Bus 2
8F34
...Repeated for Trip Bus 3
8F66
...Repeated for Trip Bus 4
8F98
...Repeated for Trip Bus 5
8FCA
...Repeated for Trip Bus 6
FlexElement (Read/Write Setting) (8 modules)
9000
FlexElement 1 Function
9001
FlexElement 1 Name
9004
FlexElement 1 InputP
9005
FlexElement 1 InputM
9006
FlexElement 1 Compare
9007
FlexElement 1 Input
9008
FlexElement 1 Direction
9009
FlexElement 1 Hysteresis
900A
FlexElement 1 Pickup
900C
FlexElement 1 DeltaT Units
900D
FlexElement 1 DeltaT
GE Multilin
RANGE
0 to 1
0 to 4294967295
0 to 600
0 to 600
0 to 4294967295
0 to 1
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 1
---
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 1
0.1 to 50
-90 to 90
0 to 2
20 to 86400
B30 Bus Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
1
F300
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F102
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
---
F206
---
1
F600
---
1
F600
---
1
F516
---
1
F515
---
1
F517
%
0.1
F001
pu
0.001
F004
---
1
F518
---
1
F003
DEFAULT
B
0 (Disabled)
0
0
0
0
0 (Disabled)
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
"FxE 1"
0
0
0 (LEVEL)
0 (SIGNED)
0 (OVER)
30
1000
0
(Milliseconds)
20
B-43

Advertisement

Table of Contents
loading

This manual is also suitable for:

B30

Table of Contents