GENERAL PRODUCT SPECIFICATION
6.0
Environmental characteristics
The following sections define the interference and
susceptibility condition limits that might occur
between external environment and the display device.
6.1
Susceptibility of display to external environment
Operating
- Air pressure : 600-1100 mBAR
Storage
- Temperature : -30 to 60 degree C
- Humidity
- Altitude
- Air pressure
6.2
Transportation tests
Standard
Drop
Sequence
Test
Sequence
Vibration
Test
20.1" TFT UXGA LCD Monitor
TYPE
BRAND : PHILIPS
2005-12-02
Jerry Chen
- Temperature : 0 to 35 degree C
: 80% max
- Humidity
: 0-3658m
- Altitude
: 85% max ( < 40
: 0-12192m
: 300-1100 mBAR
Note: recommend at 5 to 35°C, Humidity less than 60 %
Philips UAN-D1400
61.0 cm
Height
1 corner
3 edges
(Room temp) 6 faces
Electrical function ok
Mechanical function ok
Test
No serious damage on set appearance
Result
(Room temp 20° C~23° C, humidity 40%~65%)
(1) PACKAGING
5~500 Hz, 0.73 Grms,Truck spectrum 30 min
(2) OPERATING
10-55-10, 0.35 mm amplitude, 30 min. /axis. 3axes
Electrical function ok
Test
Mechanical function ok
Result
No serious damage on set appearance