Philips 200P7ES/00 Service Manual page 25

20.1" lcd monitor
Hide thumbs Also See for 200P7ES/00:
Table of Contents

Advertisement

Re-programming Digital DDC IC
Step 1: After initialize alignment box, connecting all cables and
box as shown in Fig. 24
Fig.24
Step 2: Read DDC data from monitor
Click
icon as shown in Fig. 25 from the tool bar to bring up
1.
the Channels "Configuration Setup" windows as shown in Fig. 26.
2. Select the DDC2Bi as the communication channel.
As shown in Fig. 26.
3. Click OK button to confirm your selection.
4. Click
icon (Read EDID function) to read DDC EDID data from
monitor. The EDID codes will display on screen as shown in Fig. 27.
To Printer port
Fig. 27
DDC Instructions
Step 3: Modify DDC data (verify EDID version, week, year)
Click
1.
DC 8~12V
DC 8~12V
Power
indicator
Step 4: Modify DDC data (Monitor Serial No.)
Click
1.
Fig. 25
Fig. 26
(new function) icon from the tool bar, bring up
Step 1 of 9 as shown in Fig. 28 .
EDID45 DDC application provides the function selection and
text change (select & fill out) from Step 1 to Step 9.
To Printer port
To Printer port
DC 8~12V
To Monitor
D-sub/DVI cable
To Monitor
To Monitor
D-sub/DVI cable
D-sub cable
Power
indicator
Fig. 28
, bring up Fig. 29. Then select Digital Signal as below
Next
200P7 LCD
25
Go to cover page
Fig. 29
Fig. 30