Spectrophotometer Unit not connected.

Spectrophotometer Unit not connected.
Cause
The Spectrophotometer Unit is not installed correctly.

Spectrophotometer Sensor not mounted.

Spectrophotometer Sensor not mounted.
Cause
The Spectrophotometer Sensor to be loaded
into the Spectrophotometer Carriage is not in-
stalled correctly.

Spectrophotometer Unit Calibration white tile error.

Spectrophotometer Unit Calibration white tile error.
Cause
The White Calibration Tile is not
installed.
The White Calibration Tile is
dirty.
The performance of part of the
Spectrophotometer Sensor may
be impaired.

Spectrophotometer Unit eject guide not mounted.

Spectrophotometer Unit eject guide not mounted.
The Spectrophotometer Eject Guide is installed incorrectly,
such as being installed askew, or not pushed in all the way.
There is a foreign object on the Spectrophotometer Eject
Guide.
The performance of part of the Spectrophotometer Unit may
be impaired.

Spectrophotometer Unit Backing plate error.

Spectrophotometer Unit Backing plate error.
Cause
The White/Black Backing Plate is not instal-
led correctly.
The White/Black Backing Plate is soiled.

Spectrophotometer Sensor Cover open.

Spectrophotometer Sensor Cover open.
The Spectrophotometer Sensor Cover of the Spectrophotometer
Unit is open.

Spectrophotometer Unit cover open.

Spectrophotometer Unit cover open.
The Spectrophotometer Unit Cover of the Spectrophotometer Unit is
open.
User's Guide
Turn off the power and reinstall the Spectrophotometer Unit.
Turn off the power, and reinstall by pushing the two connectors all the way into the Spec-
trophotometer Sensor.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (op-
tion).")
Install the White Calibration Tile.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")
Remove, clean, and reinstall the White Calibration Tile.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")
If this message is still displayed after cleaning the White Calibration Tile, we recommend adjusting the
Spectrophotometer Sensor.
Contact your Canon dealer for more information on adjustment services.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")
Cause
Remove and correctly attach the White/Black Backing Plate, and then press the OK button.
(See "Switching the White/Black Backing Plate (Optional) Color.")
Clean the White/Black Backing Plate and then press the OK button.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")
Cause
Cause
Corrective Action
Corrective Action
P.859
Corrective Action
Make sure that the Spectrophotometer Eject Guide is loaded in the correct
position, push it in all the way, and press the OK button.
Remove the foreign object and press the OK button.
Turn off the printer, wait a while, and then turn it on again.
If the same message is displayed again, contact your Canon dealer for as-
sistance.
Corrective Action
Close the Spectrophotometer Sensor Cover and press the OK but-
ton.
Close the Spectrophotometer Unit Cover and press the OK button.
Spectrophotometer Unit not connected.
P.859
P.843
P.859
Corrective Action
P.746
P.843
Corrective Action
Corrective Action