Inserting/Replacing The Battery; Initial Operation - Bosch GMS120 Instruction Manual

Hide thumbs Also See for GMS120:
Table of Contents

Advertisement

Detectores de metales y otros materiales digitales GMS120 bosch manual ingles www.viaindustrial.com
Display Elements (see figure A)
a Switched-off audio signal indicator
b Warning-function indicator
c Indication of the object type "Non-metal object"
d Indication of the object type "Non-magnetic metal"
e Indication of the object type "Magnetic metal"
f Indication of the object type "Live conductor"
g T emperature control indicator
h Battery indicator
i Measuring indicator
j Fine scale
k Indication "CENTER"
Technical Data
Digital Detector
Article number
Maximum scanning depth*
– Ferrous metals
– Non-ferrous metals (copper)
– Live conductors 110–230 V
(voltage applied)**
– Wood
Automatic switch-off after approx.
Operating temperature
Storage temperature
Battery
Operating life time, approx.
Weight according to
EPTA-Procedure 01/2003
Degree of protection
*depending on operating mode, material and size of the objects, as well
as material and condition of the base material
**less scanning depth for wires/conductors that are not "live"
Intermsofaccuracy,themeasuringresultcanbeinferiorincase
of unfavourable surface quality of the base material.
Detectores de metales y otros materiales digitales GMS120 bosch manual ingles www.viaindustrial.com
Assembly

Inserting/Replacing the Battery

Alkali-manganese batteries are recommended for the meas-
uring tool.
To open the battery lid 14, press the latch 15 in the direction
of the arrow and fold up the battery lid. Insert the supplied
battery .Payattentionthatthepolarityiscorrect,accordingto
the representation on the inside of the battery lid.
The battery indicator h always indicates the current battery
status:
– Battery fully charged
– Battery has 2/3 of its capacity or less
– Battery has 1/3 of its capacity or less
– Please change battery
If the measuring tool is not used for a long period of
GMS 120
time, the battery must be removed. The battery can cor-
3 601 K81 0..
rode or discharge itself over long periods.
120 mm
Operation
80 mm
Protect the measuring tool against moisture and direct
50 mm
sun light.
38 mm
Do not subject the measuring tool to extreme tempera-
5 min
tures or variations in temperature. In case of large var-
iations in temperature, allow the measuring tool to ad-
–10 °C...+50 °C
just to the ambient temperature before switching it on.
–20 °C...+70 °C
In case of extreme temperatures or variations in tempera-
1 x 9 V 6LR61
ture, the accuracy of the measuring tool and the display in-
5h
dication can be impaired.
Use or operation of transmitting systems, such as
270 g
WLAN, UMTS, radar, transmitter masts or microwaves,
in the close proximity can influence the measuring
IP 54 (dust and splash
function.
water protected)

Initial Operation

Switching On and Off
Beforeswitchingthemeasuringtoolon,makesurethat
the sensor area 12 is not moist. If required, dry the meas-
uring tool using a soft cloth.
If the measuring tool was subject to an extreme tem-
perature change, allow it to adjust to the ambient tem-
perature before switching on.
To switch on the measuring tool, press the On/Off button 5.
To switch off the measuring tool, press the On/Off button 5
again.
When no button on the measuring tool is pressed for approx.
5 minutes and when no objects are detected, the measuring
tool automatically switches off to save the battery .
Switching the Display Illumination On/Off
The display illumination can be switched on/off with display-
illumination button 6.
Switching the Audio Signal On/Off
The audio signal can be switched on/off with the audio signal
button 7. When the audio signal is switched off, indication a
appears on the display.
English | 11