10.3 Control

Problem
Temperature does
not rise.
The control output
remains ON status.
The control output
remains OFF status.
If any unexplained malfunctions occur, make inquiries at our agency or us.

11. Character table

Photocopiable material
[Main setting mode]
Character
[Sub setting mode]
Character
• The sensor is out of order.
Replace the sensors.
• Check whether the sensor is securely mounted to the
instrument input terminal.
Check whether control output terminals are securely
mounted to the actuator input terminals.
Mount the sensor or control output terminal securely.
• Check whether the wiring of sensor or control output terminals
is correct.
• OUT1 low limit value is set to 100% or higher in Auxiliary
function setting mode 2.
Set it to a suitable value while in Auxiliary function setting
mode 2.
• OUT1 high limit value is set to 0% or less in Auxiliary
function setting mode 2.
Set it to a suitable value while in Auxiliary function setting
mode 2.
Setting item
SV1
SV2
Setting item
AT
Auto-reset
OUT1 proportional band
OUT2 proportional band
Integral time
Derivative time
ARW
OUT1 proportional cycle
OUT2 proportional cycle
A1 value
A2 value
HB (Heater burnout alarm) value
Presumed cause and solution
Default value
0
0
Default value
10
1.0 times
200 seconds
50 seconds
50%
Relay contact output: 30sec
Non-contact voltage output: 3sec
Relay contact output: 30sec
Non-contact voltage output: 3sec
0
0
0.0A
46
Data
Data