SW6 No.2 CED signal send
Used to set YES/NO of CED signal send.
This is valid only when SW52-7 (V.34 mode function) is OFF.
This is because ANSam signal send is necessary for V.34 mode.
When set to 1, CED signal send is performed.
When set to 0, CED signal send is not performed.
Default: 1 (Yes)
SW6 No.3 CSI transmission
Used to set YES/NO of CSI signal send.
CSI signal includes the sender's number.
Default: 1 (Yes)
SW6 No.4 DIS reception confirmation in G3 send
Used to set YES/NO of DIS receive check in G3 mode send.
When set to 1, DIS receive twice is checked.
When set to 0, DIS once is checked when "NSF/DIS" is received;
and DIS twice is checked when NSF is not received.
Default: 0 (Once in NFS reception, 2 time in DIS reception)
SW6 No.5 Inhibited to use
SW6 No.6 EOL detection timer
Used to set detection timer of EOL (EndOfLine) in Phase C receive.
Default: 0 (13sec)
SW6 No.7 Countermeasure for echo in reception (CED
tone send interval)
Used to set the interval from CED send to FSK signal send of DIS.
Default: 1 (500ms)
SW6 No.8 Countermeasure for echo in transmission
(After reception of DIS, hold time up to signal send is
set.)
Used to set the interval from DIS receive to DSC signal send.
Default: 0 (500ms)
SW7 No.1 Dial tone ON/OFF detection time lower limit
(Intermittent detection)
Used to set the minimum required time for detection of dial tone
when the dial tone detection is set to "YES" and the kind of the dial
tone detection is set to "Continuous."
Default: 0 (100ms)
SW7 No.2 Dial tone detection
Used to set whether dial tone is detected or not when calling out.
When set to 1, dial tone is detected before calling out.
When set to 0, dial tone is not detected and dialing is made after a
certain time (3.5sec).
Default: 0 (No)
SW7 No.3 Busy tone detection
Used to set YES/NO of busy tone detection when calling out.
Default: 1 (Yes)
SW7 No.4 Dial tone monitoring time
Used to set the monitoring time when detecting dial tone.
Default: 0 (5sec)
SW7 No.5 Dial tone ON/OFF detection time upper limit
(Intermittent detection)
Used to set the upper limit time for detection of dial tone when the
dial tone detection is set to "YES" and the kind of the dial tone detec-
tion is set to "Intermittent."
If a dial tone is detected for more than this upper limit time, it is not
considered as a dial tone.
Default: 0 (700ms)
SW7 No.6 Max. length of reception
Used to set max. length of reception for long document.
Default: 0 (1.5m)
AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 23
SW7 No.7, No.8 Destination display time when one-
touch key is pressed
Used to set the time from displaying the destination to the next oper-
ation in one-touch dial or reduction dial.
Default: 0 0 (2sec)
SW8 No.1 Memory transmission/direct transmission
default setup
Used to set whether memory send is ON or direct send is made
(OFF) in the memory mode when pressing [Clear All] key or auto
clear.
Default: 0 (Memory transmission)
SW8 No.2 Proxy reception
Used to set whether proxy reception is enabled or not.
When set to 0, under the following error status, auto receive is not
made in auto receive mode.
• Cover open
• Unit error (Toner, drum, developing-related errors)
• Recording paper JAM
• Document JAM
• Recording paper empty
When set to 1, proxy reception is allowed.
Default: 1 (Yes)
SW8 No.3 Inhibited to use
SW8 No.4 Quick online send
Used to set whether quick online send function is enabled or not.
When set to 0, send in memory mode ON is made in memory send.
When set to 1, send in memory mode ON is made in quick online
send.
Default: 1 (Yes)
SW8 No.5 Remote select function
Used to set whether remote select function is enabled or not.
Default: 1 (Yes)
SW8 No.6–No.8 Number of times of CNG detection
Used to set the number of times of CNG detection for judgment of
detection.
Default: 3 times
SW9 No.1 Print of total communication time and total
pages
Used to set whether the total communication time and total pages
are printed on the communication report or not.
When set to 1, the total communication time and total pages are
printed on the communication report.
When set to 0, the total communication time and total pages are not
printed on the communication report.
Default: 1 (Yes)
SW9 No.2 Inhibited to use
SW9 No.3–No.8 Ringing volume pattern number
Used to set ringing volume pattern.
Default: 1
SW10 No.1 Measurement of communication time
(image)
Used to set YES/NO of measurement of communication time in
phase C. It is the communication time in the latest phase C. (Unit:
msec)
Valid only in ECM communication.
Default: 1 (Yes)
SW10 No.2 Sender's telephone number registration
Used to set whether registered sender's telephone number can be
changed or not.
Default: 0 (Allow)